Suppr超能文献

Simultaneous quantification of preactivated ifosfamide derivatives and of 4-hydroxyifosfamide by high performance liquid chromatography-tandem mass spectrometry in mouse plasma and its application to a pharmacokinetic study.

作者信息

Deroussent Alain, Skarbek Charles, Maury Adeline, Chapuis Hubert, Daudigeos-Dubus Estelle, Le Dret Ludivine, Durand Sylvère, Couvreur Patrick, Desmaële Didier, Paci Angelo

机构信息

CNRS UMR 8203, Laboratory of Vectorology and Anticancer Therapeutics, Paris-Sud University, Gustave Roussy Cancer Campus Grand Paris, Villejuif, France.

CNRS UMR 8203, Laboratory of Vectorology and Anticancer Therapeutics, Paris-Sud University, Gustave Roussy Cancer Campus Grand Paris, Villejuif, France.

出版信息

J Chromatogr B Analyt Technol Biomed Life Sci. 2015 Jun 15;992:30-5. doi: 10.1016/j.jchromb.2015.04.025. Epub 2015 Apr 20.

Abstract

The antitumor drug, ifosfamide (IFO), requires activation by cytochrome P450 (CYP) to form the active metabolite, 4-hydroxyisfosfamide (4-OHIFO), leading to toxic by-products at high dose. In order to overcome these drawbacks, preactivated ifosfamide derivatives (RXIFO) were designed to release 4-OHIFO without CYP involvement. A high performance liquid chromatography-tandem mass spectrometry (HPLC-MS/MS) method was developed for the simultaneous quantification of 4-OHIFO, IFO and four derivatives RXIFO in mouse plasma using multiple reaction monitoring. Because of its instability in plasma, 4-OHIFO was immediately converted to the semi-carbazone derivative, 4-OHIFO-SCZ. For the six analytes, the calibration curves were linear from 20 to 5000ng/mL in 50μL plasma and the lower limit of quantitation was determined at 20ng/mL with accuracies within ±10% of nominal and precisions less than 12%. Their recoveries ranged from 62 to 96% by using liquid-liquid extraction. With an improved assay sensitivity compared to analogues, the derivative 4-OHIFO-SCZ was stable in plasma at 4°C for 24h and at -20°C for three months. For all compounds, the assay was validated with accuracies within ±13% and precisions less than 15%. This method was applied to a comparative pharmacokinetic study of 4-OHIFO from IFO and three derivatives RXIFO in mice. This active metabolite was produced by some of the novel conjugates with good pharmacokinetic properties.