• 文献检索
  • 文档翻译
  • 深度研究
  • 学术资讯
  • Suppr Zotero 插件Zotero 插件
  • 邀请有礼
  • 套餐&价格
  • 历史记录
应用&插件
Suppr Zotero 插件Zotero 插件浏览器插件Mac 客户端Windows 客户端微信小程序
定价
高级版会员购买积分包购买API积分包
服务
文献检索文档翻译深度研究API 文档MCP 服务
关于我们
关于 Suppr公司介绍联系我们用户协议隐私条款
关注我们

Suppr 超能文献

核心技术专利:CN118964589B侵权必究
粤ICP备2023148730 号-1Suppr @ 2026

文献检索

告别复杂PubMed语法,用中文像聊天一样搜索,搜遍4000万医学文献。AI智能推荐,让科研检索更轻松。

立即免费搜索

文件翻译

保留排版,准确专业,支持PDF/Word/PPT等文件格式,支持 12+语言互译。

免费翻译文档

深度研究

AI帮你快速写综述,25分钟生成高质量综述,智能提取关键信息,辅助科研写作。

立即免费体验

[Evaluation of CRT images of digitized film angiographs].

作者信息

Mashita S, Ishigaki T, Ikeda M, Sakuma S

出版信息

Nihon Igaku Hoshasen Gakkai Zasshi. 1989 Aug 25;49(8):1025-37.

PMID:2594482
Abstract

X-ray sheet film images of the test chart, the vascular phantom and angiography were digitized at sampling pitch of 0.2 mm and 0.15 mm using film digitizer TFR-01 (Toshiba) and transferred to a device for image storage and display system with 1635-line display monitor (TDF-500AS, Toshiba). Comparison of image qualities between film- and CRT-images was performed in fundamental and clinical studies. Resolution of the test chart image of conventional radiography was worse on CRT than on the original film, although it was improved when film image was digitized at resolution of 0.15 mm/pixel in comparison with that at resolution of 0.2 mm/pixel. Moiré stripes which occurred due to interference were found on CRT images taken using a grid technique. On CRT images of X-ray sheet film using direct magnification technique moiré stripes were not produced because of non grid technique, and the resolution approached that of the original film. In the study using vascular phantom, the optimal image on CRT could be obtained by various image processing procedures, and image quality on CRT with resolution of 0.15 mm approached that of original film. In case of direct magnification CRT images were superior to film images. Subtraction image of the vascular phantom at resolution of 0.2 mm/pixel was obtained on CRT and compared with film subtraction image. On conventional subtraction CRT image moiré stripes impaired the image quality in comparison with the film subtraction. However, magnification subtraction image of the vascular phantom on CRT was superior to the film subtraction. The results obtained in the test chart studies and phantom studies were also confirmed in clinical studies using various kind of angiograms. In addition, ROC study using clinical angiograms showed no significant statistical differences between the original film and CRT image even with 0.2 mm matrix size. Angiographic image on CRT at resolution of 0.15 mm/pixel or less is available for clinical use in place of conventional film image.

摘要

相似文献

1
[Evaluation of CRT images of digitized film angiographs].
Nihon Igaku Hoshasen Gakkai Zasshi. 1989 Aug 25;49(8):1025-37.
2
Contrast mapping and evaluation for electronic X-ray images on CRT display monitor.阴极射线管(CRT)显示器上电子X射线图像的对比度映射与评估。
IEEE Trans Med Imaging. 1997 Dec;16(6):772-84. doi: 10.1109/42.650874.
3
Use of personal computers and digitized film angiograms to produce subtraction angiograms.
Radiographics. 1996 Mar;16(2):401-7. doi: 10.1148/radiographics.16.2.8966296.
4
[The spatial resolution of the digital storage phosphor system. The monitor and film compared].[数字存储荧光体系统的空间分辨率。与显示器和胶片的比较]
Radiol Med. 1995 Sep;90(3):298-302.
5
[Digital radiography: fundamentals and future potentials].[数字放射摄影:基础与未来潜力]
Nihon Igaku Hoshasen Gakkai Zasshi. 1989 Jan 25;49(1):1-14.
6
Comparison of diagnostic accuracy of breast masses using digitized images versus screen-film mammography.使用数字化图像与乳腺钼靶摄影对乳腺肿块诊断准确性的比较。
Acta Radiol. 2008 Jul;49(6):618-22. doi: 10.1080/02841850802014610.
7
Permanent Electronic Storage of Angiographic Images in the Catheterization Laboratory: High-Resolution and Real-Time Acquisition on Optical Laserdiscs.
J Invasive Cardiol. 1997 Mar;9(2):96-108.
8
Advantages of magnification in digital phase-contrast mammography using a practical X-ray tube.使用实用X射线管进行数字相衬乳腺摄影时放大的优势。
Eur J Radiol. 2008 Dec;68(3 Suppl):S69-72. doi: 10.1016/j.ejrad.2008.04.041. Epub 2008 Jun 26.
9
[Hard-copy (film) versus soft-copy (CRT) reading performance between compressed and uncompressed images: SOLs in abdominal CT images].[压缩图像与未压缩图像之间硬拷贝(胶片)与软拷贝(阴极射线管)阅读性能比较:腹部CT图像中的类固脂]
Nihon Igaku Hoshasen Gakkai Zasshi. 1999 Sep;59(11):521-5.
10
Angiographic film subtraction using a laser digitizer and computer processing.使用激光数字化仪和计算机处理的血管造影胶片减影法。
J Digit Imaging. 1998 Nov;11(4):159-67. doi: 10.1007/BF03178078.