Yasui Takeshi, Hayashi Kenta, Ichikawa Ryuji, Cahyadi Harsono, Hsieh Yi-Da, Mizutani Yasuhiro, Yamamoto Hirotsugu, Iwata Tetsuo, Inaba Hajime, Minoshima Kaoru
Opt Express. 2015 May 4;23(9):11367-77. doi: 10.1364/OE.23.011367.
Real-time measurement of the absolute frequency of continuous-wave terahertz (CW-THz) radiation is required for characterization and frequency calibration of practical CW-THz sources. We proposed a method for real-time monitoring of the absolute frequency of CW-THz radiation involving temporally parallel, i.e., simultaneous, measurement of two pairs of beat frequencies and laser repetition frequencies based on dual THz combs of photocarriers (PC-THz combs) with different frequency spacings. To demonstrate the method, THz-comb-referenced spectrum analyzers were constructed with a dual configuration based on dual femtosecond lasers. Regardless of the presence or absence of frequency control in the PC-THz combs, a frequency precision of 10(-11) was achieved at a measurement rate of 100 Hz. Furthermore, large fluctuation of the CW-THz frequencies, crossing several modes of the PC-THz combs, was correctly monitored in real time. The proposed method will be a powerful tool for the research and development of practical CW-THz sources, and other applications.