Kimura H, Sohmura T, Watanabe T
Shika Zairyo Kikai. 1989 Mar;8(2):137-43.
The three dimensional shape measurement system of teeth was improved. The system was assembled by using a high precision laser displacement meter and computer controlled scanning machine (CAMM-3). At the fissure of the occlusal plane, the abnormal data caused by multiple scattering of the reflected beam were observed, but they were dissolved by painting the stone model teeth gray and measured by using a laser displacement meter of MD-40 type with a short measurement length. Another error observed when the reflected beam was shielded by the model tooth itself, was corrected by connecting some data which were measured by rotating the teeth model on the gonio stage. A software program was composed to connect the data. The accuracy of measurement of this system was examined on the slope of a 7 abutment tooth. When the model teeth were measured without tilting, the difference between the true value and the measured value was -240 microns (-2.8%). However, by tilting the model teeth +/- 20 degrees on the gonio stage and connecting a couple of data obtained with two tilting angles by means of the software program, the difference was considerably decreased into + 10 microns and the accuracy was + 0.1%.(ABSTRACT TRUNCATED AT 250 WORDS)
牙齿三维形状测量系统得到了改进。该系统是通过使用高精度激光位移计和计算机控制扫描机(CAMM - 3)组装而成的。在咬合面的裂隙处,观察到了由反射光束的多次散射引起的异常数据,但通过将石膏模型牙齿涂成灰色并使用测量长度较短的MD - 40型激光位移计进行测量,这些异常数据得以消除。当反射光束被模型牙齿自身遮挡时观察到的另一个误差,通过连接在测角台上旋转牙齿模型所测量的一些数据得到了校正。编写了一个软件程序来连接这些数据。在一个7基牙的斜坡上对该系统的测量精度进行了检验。当模型牙齿不倾斜进行测量时,真值与测量值之间的差异为 - 240微米(-2.8%)。然而,通过在测角台上将模型牙齿倾斜±20度,并借助软件程序连接通过两个倾斜角度获得的几组数据,差异大幅减小至 + 10微米,精度为 + 0.1%。(摘要截于250字)