Suppr超能文献

在气相色谱/质谱联用仪(GC/MS)分析之前,使用石墨烯涂层固相微萃取纤维对主流卷烟烟雾中的多环芳烃进行灵敏且选择性的测定。

Sensitive and selective determination of polycyclic aromatic hydrocarbons in mainstream cigarette smoke using a graphene-coated solid-phase microextraction fiber prior to GC/MS.

作者信息

Wang Xiaoyu, Wang Yuan, Qin Yaqiong, Ding Li, Chen Yi, Xie Fuwei

机构信息

Zhengzhou Tobacco Research Institute of CNTC, Zhengzhou 450001, China.

Key Laboratory of Analytical Chemistry for Living Biosystems, Institute of Chemistry, Chinese Academy of Sciences, Beijing 100190, China.

出版信息

Talanta. 2015 Aug 1;140:102-108. doi: 10.1016/j.talanta.2015.03.030. Epub 2015 Mar 21.

Abstract

A simple method has been developed for the simultaneous determination of 16 polycyclic aromatic hydrocarbons (PAHs) in mainstream cigarette smoke. The procedure is based on employing a homemade graphene-coated solid-phase microextraction (SPME) fiber for extraction prior to GC/MS. In comparison to commercial 100-μm poly(dimethyl siloxane) (PDMS) fiber, the graphene-coated SPME fiber exhibits advantageous cleanup and preconcentration efficiencies. By collecting the particulate phase 5 cigarettes, the LODs and LOQs of 16 target PAHs were 0.02-0.07 and 0.07-0.22 ng/cigarette, respectively, and all of the linear correlation efficiencies were larger than 0.995. The validation results also indicate that the method has good repeatability (RSD between 4.2% and 9.5%) and accuracy (spiked recoveries between 80% and 110%). The developed method was applied to analyze two Kentucky reference cigarettes (1R5F and 3R4F) and six Chinese brands of cigarettes. In addition, the PAH concentrations in the particulate phase of the smoke from the 1R5F Kentucky cigarettes were in good agreement with recently reported results. Due to easy operation and good validation results, this SPME-GC/MS method may be an excellent alternative for trace analysis of PAHs in cigarette smoke.

摘要

已开发出一种简单方法,用于同时测定主流卷烟烟气中的16种多环芳烃(PAHs)。该方法基于在GC/MS分析前,使用自制的石墨烯涂层固相微萃取(SPME)纤维进行萃取。与商用100μm聚二甲基硅氧烷(PDMS)纤维相比,石墨烯涂层SPME纤维具有更好的净化和预浓缩效率。通过收集5支卷烟的颗粒相,16种目标PAHs的检出限和定量限分别为0.02 - 0.07 ng/支和0.07 - 0.22 ng/支,且所有线性相关系数均大于0.995。验证结果还表明该方法具有良好的重复性(相对标准偏差在4.2%至9.5%之间)和准确性(加标回收率在80%至110%之间)。所开发的方法应用于分析两种肯塔基参考卷烟(1R5F和3R4F)以及六个中国品牌的卷烟。此外,1R5F肯塔基卷烟烟气颗粒相中PAH的浓度与最近报道的结果高度一致。由于操作简便且验证结果良好,这种SPME - GC/MS方法可能是卷烟烟气中PAHs痕量分析的一种极佳替代方法。

文献检索

告别复杂PubMed语法,用中文像聊天一样搜索,搜遍4000万医学文献。AI智能推荐,让科研检索更轻松。

立即免费搜索

文件翻译

保留排版,准确专业,支持PDF/Word/PPT等文件格式,支持 12+语言互译。

免费翻译文档

深度研究

AI帮你快速写综述,25分钟生成高质量综述,智能提取关键信息,辅助科研写作。

立即免费体验