In this work, polymerized high internal phase emulsion (polyHIPE) monoliths were prepared and applied as monolithic adsorbent materials for proconcentration of trace polycyclic aromatic hydrocarbons (PAHs) from large-volume water samples. The monolithic polyHIPE columns were prepared by in situ polymerization of the continuous phase of a high internal phase emulsion (HIPE) containing styrene (STY), divinylbenzene (DVB) and glycidyl methacrylate (GMA) in pipette tips, and the resulting STY/DVB/GMA polyHIPE monoliths exhibited highly interconnected porosity and large surface areas, making them excellent candidates as adsorbents for enrichment of trace aromatic compounds. The prepared STY/DVB/GMA polyHIPE monoliths were applied to the determination of trace PAHs in environmental water samples by combing with high performance liquid chromatography-fluorescence detection (HPLC-FLD). Under the optimized experimental conditions, the polyHIPE monoliths could effectively enrich trace 13 PAHs from 500mL of water samples, the mean recoveries at four spiked levels were ranged from 80.7% to 115.0% with the relative standard deviations (RSDs) lower than 14%, and the detection limits (LODs) were ranged from 4.0 to 228pg/L. In addition, the prepared polyHIPE monolith was stable enough for more than 200 replicate extraction cycles without measurable loss of performance on the enrichment of PAHs, and good column-to-column repeatability was obtained with RSD less than 13%. The proposed method was applied to simultaneous analysis of 13 PAHs in water samples with satisfactory recoveries.

摘要

在本工作中,制备了聚合高内相乳液(polyHIPE)整体柱,并将其用作整体吸附材料,用于从大体积水样中预富集痕量多环芳烃(PAHs)。通过在移液管尖端原位聚合含有苯乙烯(STY)、二乙烯基苯(DVB)和甲基丙烯酸缩水甘油酯(GMA)的高内相乳液(HIPE)的连续相来制备整体式polyHIPE柱,所得的STY/DVB/GMA polyHIPE整体柱表现出高度互连的孔隙率和大表面积,使其成为富集痕量芳香族化合物的理想吸附剂候选材料。将制备的STY/DVB/GMA polyHIPE整体柱与高效液相色谱 - 荧光检测(HPLC - FLD)相结合,用于环境水样中痕量PAHs的测定。在优化的实验条件下,polyHIPE整体柱能够有效地从500mL水样中富集痕量的13种PAHs,四个加标水平下的平均回收率在80.7%至115.0%之间,相对标准偏差(RSDs)低于14%,检测限(LODs)在4.0至228pg/L之间。此外,制备的polyHIPE整体柱足够稳定,可进行超过200次重复萃取循环,而在PAHs富集性能上没有可测量的损失,并且柱间重复性良好,RSD小于13%。所提出的方法应用于水样中13种PAHs的同时分析,回收率令人满意。