Augmented blood pressure (BP) variability is associated with cardiovascular diseases in some clinical conditions including hypertension. Drugs that effectively reduce BP variability need to be identified, while few animal models are currently available to study BP variability. Here, we report that hypertension induced by continuous infusion of angiotensin II (Ang II) was accompanied by increased BP variability in rats.
Ang II was subcutaneously infused at a rate of 240 pmol/kg/min into male Wistar rats undergoing intraperitoneal implantation of a transmitter connected to an abdominal aortic catheter. BP was continuously monitored via a telemetry system before and after the Ang II infusion in a conscious, unrestrained condition. BP variability was evaluated by coefficient of variation (CV) of BP levels measured every 15 minutes. In addition, spontaneously hypertensive and Wistar-Kyoto rats (SHR and WKY) were subjected to the BP monitoring experiment at 15 weeks of age.
Both systolic and diastolic BP levels were significantly elevated following the Ang II infusion. Similarly, CVs of systolic and diastolic BP in the Ang II infusion group were significantly higher than in the vehicle group upon 1 and 2 weeks of the infusion. Meanwhile, CVs of systolic and diastolic BP of SHR were in a range similar to those of WKY despite significantly higher BP than in WKY.
Hypertension induced by the continuous infusion of Ang II was accompanied by augmented BP variability in rats, an effect assumed to be at least in part, independent of BP elevation.
在包括高血压在内的一些临床情况下,血压(BP)变异性增加与心血管疾病相关。需要确定能有效降低血压变异性的药物,而目前用于研究血压变异性的动物模型很少。在此,我们报告持续输注血管紧张素II(Ang II)诱导的高血压伴有大鼠血压变异性增加。
以240 pmol/kg/分钟的速率将Ang II皮下输注到接受腹腔内植入与腹主动脉导管相连的发射器的雄性Wistar大鼠体内。在清醒、不受约束的状态下,通过遥测系统在输注Ang II前后连续监测血压。通过每15分钟测量一次的血压水平变异系数(CV)评估血压变异性。此外,对自发性高血压大鼠和Wistar-Kyoto大鼠(SHR和WKY)在15周龄时进行血压监测实验。
输注Ang II后,收缩压和舒张压水平均显著升高。同样,在输注1周和2周时,Ang II输注组的收缩压和舒张压CV显著高于载体组。同时,尽管SHR的血压显著高于WKY,但其收缩压和舒张压的CV与WKY的范围相似。
持续输注Ang II诱导的高血压伴有大鼠血压变异性增加,这种效应至少部分被认为与血压升高无关。