Consecutive assessment of FA and ADC values of normal lumbar nerve roots from the junction of the dura mater.

作者信息

Miyagi Ryo, Sakai Toshinori, Yamabe Eiko, Yoshioka Hiroshi

机构信息

Department of Orthopedics, The University of Tokushima Graduate School, Tokushima, Japan.

Department of the Radiological Sciences, University of California, Irvine, School of Medicine, Irvine, CA, 92868, USA.

出版信息

BMC Musculoskelet Disord. 2015 Jun 27;16:156. doi: 10.1186/s12891-015-0576-4.

Abstract

BACKGROUND

Diffusion weighted imaging (DWI) and diffusion tensor imaging (DTI) are widely used in the evaluation of the central nervous system and recently have been reported as a potential tool for diagnosis of the peripheral nerve or the lumbar nerve entrapment. The purpose of this study was to evaluate consecutive changes in apparent diffusion coefficient (ADC) and fractional anisotropy (FA) values of normal lumbar nerve roots from the junction of the dura mater.

METHODS

The lumbar spinal nerves were examined in 6 male healthy volunteers (mean age, 35 years) with no experiences of sciatica, with a 3.0-T MR unit using a five-element phased-array surface coil. DTI was performed with the following imaging parameters: 11084.6/73.7 ms for TR/TE; b-value, 800 s/mm2; MPG, 33 directions; slice thickness, 1.5 mm; and total scan time, 7 min 35 s. ADC and FA values at all consecutive points along the L4, L5 and S1 nerves were quantified on every 1.5 mm slice from the junction of the dura mater using short fiber tracking.

RESULTS

ADC values of all L4, 5, and S1 nerve roots decreased linearly up to 15 mm from the dura junction and was constant distally afterward. ADC values in the proximal portion demonstrated S1 > L5 > L4 (p < 0.05). On the other hand, FA values increased linearly up to 15 mm from the dura junction, and was constant distally afterward. FA values in the proximal portion showed L4 > L5 > S1 (p < 0.05).

CONCLUSION

Our study demonstrated that ADC and FA values of each L4, 5, and S1 at the proximal portion from the junction of the dura matter changed linearly. It would be useful to know the normal profile of DTI values by location of each nerve root so that we can detect subtle abnormalities in each nerve root.

摘要

背景

扩散加权成像(DWI)和扩散张量成像(DTI)在中枢神经系统评估中被广泛应用,最近有报道称其可作为诊断周围神经或腰神经卡压的潜在工具。本研究的目的是评估正常腰神经根从硬脑膜交界处起表观扩散系数(ADC)和各向异性分数(FA)值的连续变化情况。

方法

对6名无坐骨神经痛病史的男性健康志愿者(平均年龄35岁)的腰脊神经进行检查,使用3.0-T磁共振成像仪及五元素相控阵表面线圈。DTI的成像参数如下:重复时间(TR)/回波时间(TE)为11084.6/73.7 ms;b值为800 s/mm²;多平面梯度(MPG)为33个方向;层厚为1.5 mm;总扫描时间为7分35秒。使用短纤维追踪技术,在从硬脑膜交界处起的每1.5 mm层面上,对L4、L5和S1神经沿线所有连续点的ADC和FA值进行量化。

结果

所有L4、L5和S1神经根的ADC值从硬脑膜交界处起至15 mm处呈线性下降,之后在远端保持恒定。近端部分的ADC值显示S1>L5>L4(p<0.05)。另一方面,FA值从硬脑膜交界处起至15 mm处呈线性增加,之后在远端保持恒定。近端部分的FA值显示L4>L5>S1(p<0.05)。

结论

我们的研究表明,从硬脑膜交界处起的近端部分,各L4、L5和S1神经根的ADC和FA值呈线性变化。了解各神经根位置的DTI值正常情况,有助于我们检测各神经根的细微异常。