出版信息

MethodsX. 2014 Sep 23;1:207-11. doi: 10.1016/j.mex.2014.09.002. eCollection 2014.

Abstract

This work provides a short and easy protocol that allows the analysis of both methanol and ethanol in the static headspace of olive oil. The procedure avoids any kind of sample pre-treatment beyond that of heating the oil to allow a maximum volatile concentration in the headspace of the vials. The method's LOD is 0.55 mg kg(-1) and its LOQ is 0.59 mg kg(-1). Advantages of this method are:•Simultaneous determination of methanol and ethanol (the pre-existing Spanish specification UNE-EN 14110 only analyses methanol).•No need of equipment modifications (standard split injectors work perfectly). Use of a highly polar capillary GC column, leading in most cases to chromatograms in which only three dominant peaks are present - methanol, ethanol, and propanol (that is extremely positive for easy interpretation of results).•Use of an internal standard (1-propanol) to determine the concentration of the analytes, reducing the presence of error sources.

摘要

本研究提供了一种简短且简便的方法,可用于分析橄榄油静态顶空中的甲醇和乙醇。该方法除了将油加热以使小瓶顶空中的挥发性物质浓度达到最大外,无需进行任何形式的样品预处理。该方法的检测限为0.55 mg kg⁻¹,定量限为0.59 mg kg⁻¹。该方法的优点包括:

• 可同时测定甲醇和乙醇(西班牙现行标准UNE-EN 14110仅分析甲醇)。

• 无需对设备进行改造(标准分流进样器即可完美运行)。使用高极性毛细管气相色谱柱,多数情况下可得到仅含三个主峰——甲醇、乙醇和丙醇的色谱图(这对于结果的轻松解读极为有利)。

• 使用内标物(1-丙醇)来测定分析物的浓度,减少误差来源。