Gambarini Gianluca, Plotino Gianluca, Piasecki Lucila, Al-Sudani Dina, Testarelli Luca, Sannino Gianpaolo
Endodontics Unit, Department of Oral and Maxillofacial Sciences, "Sapienza" University of Rome, Italy.
PUC University, Curitiba, Brasil.
Ann Stomatol (Roma). 2015 May 18;6(1):6-9. eCollection 2015 Jan-Mar.
To compare the effect of brushing motion on torsional and cyclic fatigue resistance of TF Adaptive instruments after clinical use.
20 packs of TFA small sequence (SybronEndo, Orange, CA, USA) were used for this study and divided into two groups. Each instrument prepared one resin tooth, consisting in 4 canals with a complex anatomy. In group A, no brushing motion was performed. In group B, after the green instrument reached the working length, brushing motion with circumferential filing was performed for 15 seconds in each canal (overall 1 minute). All the instruments were then subjected to cyclic fatigue test and mean values and standard deviation for time to fracture were evaluated. Data were subjected to one-way analysis of variance and Bonferroni t-test procedure with a significance set at P < 0.05.
No instruments were broken during preparation of root canals. Two TF Adaptive green and 5 yellow showed unwinding after intracanal clinical use. No statistically significant differences were found between green instruments of both groups (P > 0.05), while a statistically significant difference was found between the yellow instruments (P < 0.05), with group B showing an higher resistance to cyclic fatigue.
A prolonged passive brushing motion did not adversely affected mechanical resistance of the instrument used for this purpose. Resistance to both deformations and cyclic fatigue of the second instrument within the TFA small sequence was enhanced by the coronal flaring provided by the brushing action of the first instrument used.
比较刷牙动作对TF自适应器械临床使用后抗扭转和循环疲劳性能的影响。
本研究使用20包TFA小序列器械(美国加利福尼亚州奥兰治市SybronEndo公司生产),分为两组。每个器械预备一颗树脂牙,该树脂牙有4个解剖结构复杂的根管。A组不进行刷牙动作。B组中,绿色器械到达工作长度后,在每个根管内进行15秒的圆周锉磨刷牙动作(共1分钟)。然后对所有器械进行循环疲劳测试,评估断裂时间的平均值和标准差。数据采用单因素方差分析和Bonferroni t检验,显著性水平设定为P < 0.05。
根管预备过程中无器械折断。两根TF自适应绿色器械和五根黄色器械在根管内临床使用后出现松解。两组绿色器械之间未发现统计学显著差异(P > 0.05),而黄色器械之间存在统计学显著差异(P < 0.05),B组对循环疲劳的抵抗力更高。
延长的被动刷牙动作不会对用于此目的的器械的机械性能产生不利影响。使用的第一根器械的刷牙动作所提供的冠部扩锉增强了TFA小序列中第二根器械对变形和循环疲劳的抵抗力。