Hajduk Joanna, Matysiak Jan, Kokot Piotr, Nowicki Piotr, Dereziński Paweł, Kokot Zenon J
Department of Inorganic & Analytical Chemistry, Poznan University of Medical Sciences, 6 Grunwaldzka Street, 60-780 Poznań, Poland.
Obstetrics and Gynecology Ward, Mielec District Hospital, 22a Żeromskiego Street, 39-300 Mielec, Poland.
Clin Chim Acta. 2015 Aug 25;448:174-81. doi: 10.1016/j.cca.2015.06.025. Epub 2015 Jul 9.
An alternative bioinformatics approach based on fuzzy theory statistics and linear discriminant analysis is proposed for the interpretation of MALDI MS spectra in peptide profiling. When applied, the methodology enables the establishment of a reproducible plasma preparation protocol appropriate for the evaluation of small data sets. The samples were collected from pregnant women affected by gestational diabetes mellitus (GDM), n=18 and control group, n=13. The following pre-treatment sets were tested: pipette tips with C18 stationary phase (ZipTip, Millipore and Omix, Agilent) and magnetic bead-based weak cation exchange chromatography kit (MB WCX, Bruker Daltonics). The spectra were recorded using a MALDI TOF mass spectrometer (UltrafleXtreme, Bruker Daltonics) for a mass range of m/z from 1000 to 10,000. The significant features were selected using the wrapper selection method, and two classification systems were tested: discriminant analysis (DA) and fuzzy inference system (FIS). ClinProTools software was employed to compare the usefulness of the proposed methodology. The study showed that the optimum results for MS spectra were obtained after the use of the ZipTip as pre-treatment method in plasma preparation. Chemometric analysis allowed the differentiation of the GDM group from the control with a high degree of accuracy: 0.7333 (DA) and 0.8065 (FIS).
本文提出了一种基于模糊理论统计和线性判别分析的生物信息学方法,用于解释肽谱分析中的基质辅助激光解吸电离质谱(MALDI MS)谱图。应用该方法时,能够建立适用于小数据集评估的可重复血浆制备方案。样本取自患有妊娠期糖尿病(GDM)的孕妇,n = 18,以及对照组,n = 13。测试了以下预处理方法:带有C18固定相的移液器吸头(ZipTip,密理博公司和安捷伦公司的Omix)以及基于磁珠的弱阳离子交换色谱试剂盒(MB WCX,布鲁克道尔顿公司)。使用MALDI TOF质谱仪(UltrafleXtreme,布鲁克道尔顿公司)在m/z 1000至10,000的质量范围内记录谱图。使用包装器选择方法选择显著特征,并测试了两种分类系统:判别分析(DA)和模糊推理系统(FIS)。采用ClinProTools软件比较所提出方法的有效性。研究表明,在血浆制备中使用ZipTip作为预处理方法后,可获得MS谱图的最佳结果。化学计量分析能够以高度准确性区分GDM组和对照组:0.7333(DA)和0.8065(FIS)。