Rolle Teresa, Manerba Linda, Lanzafame Pietro, Grignolo Federico M
a Department of Surgical Sciences , Eye Clinic, University of Torino , Torino , Italy.
Curr Eye Res. 2016 May;41(5):667-75. doi: 10.3109/02713683.2015.1043134. Epub 2015 Jul 22.
To evaluate the diagnostic power of the Posterior Pole Asymmetry Analysis (PPAA) from the SPECTRALIS OCT in glaucoma diagnosis and to define the correlation between the visual field sensitivity (VFS) and macular retinal thickness (MRT).
90 consecutive open-angle glaucoma patients and 23 healthy subjects were enrolled. All subjects underwent Visual Field test (Humphrey Field Analyzer, central 24-2 SITA-Standard) and SD-OCT volume scans (SPECTRALIS, Posterior Pole Asymmetry Analysis). The areas under the Receiving Operating Characteristic curve (AROC) were calculated to assess discriminating power for glaucoma, at first considering total MRT values and hemisphere MRT value and then quadrant MRT values from 16 square cells in a 8 x 8 posterior pole retinal thickness map that were averaged for a mean retinal thickness value. Structure function correlation was performed for total values, hemisphere values and for each quadrant compared to the matching central test points of the VF.
The AROCs ranged from 0.70 to 0.82 (p < 0.0001), with no significant differences between each other. The highest AROC observed was in inferior nasal quadrant. The VFS showed a strong correlation only with the corresponding MRT value s for quadrant analysis: Superior Temporal (r = 0.33, p = 0.0013), Superior Nasal (r = 0.43, p < 0.0001), Inferior Temporal (r = 0.57, p < 0.0001) and Inferior Nasal (r = 0.55, p < 0.0001).
the quadrant analysis showed statistically significant structure-function correlations and may provide additional data for the diagnostic performance of SPECTRALIS OCT.
评估SPECTRALIS OCT的后极不对称分析(PPAA)在青光眼诊断中的诊断能力,并确定视野敏感度(VFS)与黄斑视网膜厚度(MRT)之间的相关性。
纳入90例连续的开角型青光眼患者和23名健康受试者。所有受试者均接受了视野检查(Humphrey视野分析仪,中央24-2 SITA标准)和SD-OCT容积扫描(SPECTRALIS,后极不对称分析)。计算接受者操作特征曲线下面积(AROC)以评估青光眼的鉴别能力,首先考虑总MRT值和半球MRT值,然后考虑8×8后极视网膜厚度图中16个方形细胞的象限MRT值,将其平均以获得平均视网膜厚度值。对总数值、半球数值以及与VF匹配的中央测试点相比的每个象限进行结构功能相关性分析。
AROC范围为0.70至0.82(p < 0.0001),彼此之间无显著差异。观察到的最高AROC位于鼻下象限。仅象限分析中VFS与相应的MRT值显示出强相关性:颞上(r = 0.33,p = 0.0013)、鼻上(r = 0.43,p < 0.0001)、颞下(r = 0.57,p < 0.0001)和鼻下(r = 0.55,p < 0.0001)。
象限分析显示出具有统计学意义的结构-功能相关性,可为SPECTRALIS OCT的诊断性能提供额外数据。