Suppr超能文献

经会阴超声对产时头颅血肿的评估:一项双中心试点研究。

Intrapartum assessment of caput succedaneum by transperineal ultrasound: a two-centre pilot study.

作者信息

Hassan Wassim A, Eggebo Torbjorn M, Salvesen Kjell A, Lindtjorn Elsa, Lees Christoph

机构信息

Fetal Medicine Department, Rosie Hospital, Cambridge University Hospitals NHS Foundation Trust, Cambridge, UK.

Fetal Medicine Centre, Medway NHS Foundation Trust, Gillingham, Kent, UK.

出版信息

Aust N Z J Obstet Gynaecol. 2015 Aug;55(4):401-3. doi: 10.1111/ajo.12342. Epub 2015 Jul 23.

Abstract

Digital assessments of caput succedaneum are subjective; however, caput succedaneum can also be expressed as ultrasound measured skin-skull distance (SSD). In this study, we aimed to compare the clinical and ultrasound assessment of caput succedaneum (caput) in nulliparous women in the first stage of labour. Furthermore, we aimed to investigate the repeatability of ultrasound measurements. We observed a significant but low correlation between clinical and ultrasound assessments (Kappa value 0.29; P < 0.01). Interobserver repeatability for SSD showed an intraclass correlation coefficient of 0.96 (95% CI, 0.93-0.98). The mean difference for the caput measurements was -0.4 mm (95% CI, -0.85 to 0.05), and limits of agreement were -3.44 to 2.64 mm. We conclude that ultrasound measured SSD is an objective expression of caput with significant correlation with clinical assessment.

摘要

头颅血肿的数字评估具有主观性;然而,头颅血肿也可以用超声测量的头皮 - 颅骨距离(SSD)来表示。在本研究中,我们旨在比较初产妇第一产程中头颅血肿的临床评估与超声评估。此外,我们旨在研究超声测量的可重复性。我们观察到临床评估与超声评估之间存在显著但较低的相关性(Kappa值为0.29;P < 0.01)。SSD的观察者间可重复性显示组内相关系数为0.96(95%可信区间,0.93 - 0.98)。头颅测量的平均差异为 -0.4毫米(95%可信区间,-0.85至0.05),一致性界限为 -3.44至2.64毫米。我们得出结论,超声测量的SSD是头颅血肿的客观表现,与临床评估具有显著相关性。

文献AI研究员

20分钟写一篇综述,助力文献阅读效率提升50倍。

立即体验

用中文搜PubMed

大模型驱动的PubMed中文搜索引擎

马上搜索

文档翻译

学术文献翻译模型,支持多种主流文档格式。

立即体验