Suppr超能文献

双能计算机断层扫描用于监测痛风性关节炎中降尿酸治疗的效果。

Dual-energy computed tomography for monitoring the effect of urate-lowering therapy in gouty arthritis.

作者信息

Sun Ying, Chen Huiyong, Zhang Zhuojun, Ma Lili, Zhou Jianjun, Zhou Yi, Ding Yuqin, Jin Xuejuan, Jiang Lindi

机构信息

Department of Rheumatology, Zhongshan Hospital, Fudan University, Shanghai, China.

Department of Radiology, Zhongshan Hospital, Fudan University, Shanghai, China.

出版信息

Int J Rheum Dis. 2015 Nov;18(8):880-5. doi: 10.1111/1756-185X.12634. Epub 2015 Jul 28.

Abstract

OBJECTIVE

To investigate the relationships between changes in serum urate levels and dual-energy computed tomography (DE-CT) results during urate-lowering therapy (ULT) and to investigate the effects of treatment duration and drugs on changes in DE-CT results.

METHODS

Forty-four patients diagnosed with gout were enrolled in this investigation. DE-CT was conducted on the foot at baseline and the end of follow-up (6-24 months). Crystals were classified as: (i) L, number of large crystals with diameter ≥ 3 mm; (ii) S, number of small crystals with diameter < 3 mm; (iii) T, total number of crystals; and (iv) Vmax, volume of the maximal crystal.

RESULTS

Number of urate crystals (L, S as well as T) and Vmax decreased significantly through ULT. Significant decrease of urate crystal numbers and/or Vmax was observed in different follow-up groups, and the decrease in serum urate levels was positively related to the decrease of T (r = 0.43, P = 0.04) and Vmax (r = 0.63, P = 0.04). Moreover, analysis of covariance results demonstrated significant effects of treatment duration and serum urate levels on results of DE-CT.

CONCLUSION

Both urate crystal numbers and Vmax decreased significantly during ULT. Additionally, ULT duration and serum urate levels had significant effects on the decrease of Vmax and number of large crystals measured by DE-CT.

摘要

目的

研究降尿酸治疗(ULT)期间血清尿酸水平变化与双能计算机断层扫描(DE-CT)结果之间的关系,并探讨治疗持续时间和药物对DE-CT结果变化的影响。

方法

44例确诊为痛风的患者纳入本研究。在基线和随访结束时(6-24个月)对足部进行DE-CT检查。晶体分类如下:(i)L,直径≥3mm的大晶体数量;(ii)S,直径<3mm的小晶体数量;(iii)T,晶体总数;(iv)Vmax,最大晶体的体积。

结果

通过ULT,尿酸盐晶体数量(L、S以及T)和Vmax显著下降。在不同随访组中观察到尿酸盐晶体数量和/或Vmax显著下降,血清尿酸水平的下降与T的下降呈正相关(r = 0.43,P = 0.04)和Vmax的下降呈正相关(r = 0.63,P = 0.04)。此外,协方差分析结果表明治疗持续时间和血清尿酸水平对DE-CT结果有显著影响。

结论

ULT期间尿酸盐晶体数量和Vmax均显著下降。此外,ULT持续时间和血清尿酸水平对通过DE-CT测量的Vmax和大晶体数量的下降有显著影响。

文献检索

告别复杂PubMed语法,用中文像聊天一样搜索,搜遍4000万医学文献。AI智能推荐,让科研检索更轻松。

立即免费搜索

文件翻译

保留排版,准确专业,支持PDF/Word/PPT等文件格式,支持 12+语言互译。

免费翻译文档

深度研究

AI帮你快速写综述,25分钟生成高质量综述,智能提取关键信息,辅助科研写作。

立即免费体验