Suppr超能文献

The undamped and damped series elastic components of a vascular smooth muscle.

作者信息

Mulvany M J

出版信息

Biophys J. 1979 Jun;26(3):401-13. doi: 10.1016/S0006-3495(79)85261-3.

Abstract

Small arterial resistance vessels (internal diameter about 175 micrometer) have been mounted on a myograph that enabled their wall tension, T, and internal circumference, L, to be measured and controlled with a time resolution of about 4 ms. Maximally activated vessels were subjected to isometric releases (step changes in L) and isotonic releases (step changes in T) of varying extents and at two different temperatures (27 degree C and 37 degree C). The recovery from an isometric release was monotonic and did not include the two phases seen in skeletal muscles. The isotonic release response did, however, contain a velocity transient lasting about 150 ms: the velocity immediately after the release was about six times the steady shortening velocity. The form of both the isometric and isotonic release responses and their dependence on the extent of release can be explained in terms of a modified Hill model in which the "series elastic component" (SEC) is replaced by the series combination of an undamped-SED (that is, an undamped elastic element) and a damped-SEC (a Voigt element). Although the initial response to both types of release was independent of temperature, all stages of subsequent responses were temperature dependent, with Q10's in the range 1.5 - 2.0. The results suggest that the responses to isotonic and isometric releases may in part be due to active processes.

摘要
https://cdn.ncbi.nlm.nih.gov/pmc/blobs/f707/1328560/1a9106b74f9f/biophysj00290-0059-a.jpg

文献检索

告别复杂PubMed语法,用中文像聊天一样搜索,搜遍4000万医学文献。AI智能推荐,让科研检索更轻松。

立即免费搜索

文件翻译

保留排版,准确专业,支持PDF/Word/PPT等文件格式,支持 12+语言互译。

免费翻译文档

深度研究

AI帮你快速写综述,25分钟生成高质量综述,智能提取关键信息,辅助科研写作。

立即免费体验