Suppr超能文献

自由呼吸状态下幼儿非门控胸部CT的冠状动脉显影:时间分辨率的影响

Coronary artery visibility in free-breathing young children on non-gated chest CT: impact of temporal resolution.

作者信息

Bridoux Alexandre, Hutt Antoine, Faivre Jean-Baptiste, Flohr Thomas, Duhamel Alain, Pagniez Julien, Remy Jacques, Remy-Jardin Martine

机构信息

Department of Thoracic Imaging, Hospital Calmette (EA 2694), CHRU et Université de Lille, Boulevard Jules Leclerq, 59037 Lille Cedex, France.

Department of Research & Development in CT, Siemens Healthcare, Forchheim, Germany.

出版信息

Pediatr Radiol. 2015 Nov;45(12):1761-70. doi: 10.1007/s00247-015-3401-1. Epub 2015 Aug 21.

Abstract

BACKGROUND

Dual-source CT allows scanning of the chest with high pitch and high temporal resolution, which can improve the detection of proximal coronary arteries in infants and young children when scanned without general anesthesia, sedation or beta-blockade.

OBJECTIVE

To compare coronary artery visibility between higher and standard temporal resolution.

MATERIALS AND METHODS

We analyzed CT images in 93 children who underwent a standard chest CT angiographic examination with reconstruction of images with a temporal resolution of 75 ms (group 1) and 140 ms (group 2).

RESULTS

The percentage of detected coronary segments was higher in group 1 than in group 2 when considering all segments (group 1: 27%; group 2: 24%; P = 0.0004) and proximal segments (group 1: 37%; group 2: 32%; P = 0.0006). In both groups, the highest rates of detection were observed for the left main coronary artery (S1) (group 1: 65%; group 2: 58%) and proximal left anterior descending coronary artery (S2) (group 1: 43%; group 2: 42%). Higher rates of detection were seen in group 1 for the left main coronary artery (P = 0.03), proximal right coronary artery (P = 0.01), proximal segments of the left coronary artery (P = 0.02) and proximal segments of the left and right coronary arteries (P = 0.0006).

CONCLUSION

Higher temporal resolution improved the visibility of proximal coronary arteries in pediatric chest CT.

摘要

背景

双源CT能够以高螺距和高时间分辨率对胸部进行扫描,在无需全身麻醉、镇静或β受体阻滞剂的情况下进行扫描时,可提高婴幼儿近端冠状动脉的检出率。

目的

比较较高时间分辨率和标准时间分辨率下冠状动脉的可视性。

材料与方法

我们分析了93例接受标准胸部CT血管造影检查的儿童的CT图像,这些图像分别以75毫秒(第1组)和140毫秒(第2组)的时间分辨率进行重建。

结果

在考虑所有节段时,第1组冠状动脉节段的检出率高于第2组(第1组:27%;第2组:24%;P = 0.0004),近端节段也是如此(第1组:37%;第2组:32%;P = 0.0006)。在两组中,左冠状动脉主干(S1)的检出率最高(第1组:65%;第2组:58%),左冠状动脉前降支近端(S2)的检出率次之(第1组:43%;第2组:42%)。第1组左冠状动脉主干(P = 0.03)、右冠状动脉近端(P = 0.01)、左冠状动脉近端节段(P = 0.02)以及左、右冠状动脉近端节段(P = 0.0006)的检出率更高。

结论

较高的时间分辨率提高了儿童胸部CT中近端冠状动脉的可视性。