A new procedure for the extraction, preconcentration and simultaneous determination of the estrogens most used in contraception pharmaceuticals (estrone, 17β-estradiol, estriol, and 17α-ethynylestradiol), cataloged as Contaminants of Emergent Concern by the Environmental Protection Agency of the United States (US-EPA), is proposed. The developed system performs an in-syringe magnetic stirring-assisted dispersive liquid-liquid microextraction (in-syringe-MSA-DLLME) prior derivatization and gas chromatography (GC-MS). Different extraction (carbon tetrachloride, ethyl acetate, chloroform and trichloroethylene) and disperser solvents (acetone, acetonitrile and methanol) were tested. Chloroform and acetone were chosen as extraction and disperser solvent, respectively, as they provided the best extraction efficiency. Then, a multivariate optimization of the extraction conditions was carried out. Derivatization conditions were also studied to ensure the conversion of the estrogens to their respective trimethylsilyl derivatives. Low LODs and LOQs were achieved, i.e. between 11 and 82ngL(-1), and 37 and 272ngL(-1), respectively. Good values for intra and inter-day precision were obtained (RSDs≤7.06% and RSD≤7.11%, respectively). The method was successfully applied to wastewater samples.
提出了一种新的方法,用于提取、预浓缩并同时测定避孕药物中最常用的雌激素(雌酮、17β-雌二醇、雌三醇和17α-乙炔雌二醇),这些雌激素被美国环境保护局(US-EPA)列为新兴关注污染物。所开发的系统在衍生化和气相色谱(GC-MS)之前进行注射器内磁力搅拌辅助分散液液微萃取(in-syringe-MSA-DLLME)。测试了不同的萃取溶剂(四氯化碳、乙酸乙酯、氯仿和三氯乙烯)和分散剂溶剂(丙酮、乙腈和甲醇)。分别选择氯仿和丙酮作为萃取溶剂和分散剂溶剂,因为它们具有最佳的萃取效率。然后,对萃取条件进行了多变量优化。还研究了衍生化条件,以确保雌激素转化为各自的三甲基硅烷基衍生物。实现了较低的检测限和定量限,即分别在11至82ngL⁻¹和37至272ngL⁻¹之间。获得了良好的日内和日间精密度值(相对标准偏差分别≤7.06%和≤7.11%)。该方法成功应用于废水样品。