Sjöberg T, Norgren L, Steen S
Department of Surgery, Lund University, Sweden.
Lymphology. 1989 Dec;22(4):186-93.
Subcutaneous lymphatics in the lower leg were catheterized in the retrograde direction in 6 healthy male subjects. The catheter was connected to a pressure transducer, and pressure was measured during three stages of exercise including standing, tip-toeing, and running in place. Before the third stage, indomethacin (50mg) was given i.v. Rhythmic pressure waves were registered in each subject. During the second stage, when the subjects were "warmed up," the frequency (min-1) was 2.4 +/- 0.5 (mean +/- SEM). The corresponding values during tip-toeing and running were 5.8 +/- 0.7 (p less than 0.05) and 5.4 +/- 0.5 (p less than 0.05), respectively. The amplitudes (mean values between 3.2-4.7mmHg while standing) were not consistently altered during tip-toeing or running in any of the three stages. During standing there was a negative correlation between frequency and amplitude. No such correlation was found during tip-toeing or running, or after injection of indomethacin. Indomethacin did not significantly alter any of the measured parameters, but in two subjects the frequencies and amplitudes were decreased (about 50%) during standing, tip-toeing, and running.
在6名健康男性受试者中,将小腿皮下淋巴管逆行插管。导管连接到压力传感器,并在包括站立、踮脚尖和原地跑步的三个运动阶段测量压力。在第三阶段之前,静脉注射吲哚美辛(50mg)。在每个受试者中记录到有节律的压力波。在第二阶段,当受试者“热身”时,频率(次/分钟)为2.4±0.5(平均值±标准误)。踮脚尖和跑步时的相应值分别为5.8±0.7(p<0.05)和5.4±0.5(p<0.05)。在三个阶段中的任何一个阶段,踮脚尖或跑步时的振幅(站立时为3.2 - 4.7mmHg之间的平均值)均未持续改变。站立时频率与振幅呈负相关。在踮脚尖或跑步时,或注射吲哚美辛后未发现这种相关性。吲哚美辛未显著改变任何测量参数,但在两名受试者中,站立、踮脚尖和跑步时的频率和振幅均降低(约50%)。