Suppr超能文献

Fractured pericardial drain sheath: Removal technique.

作者信息

Naghi Jesse, Mahmud Ehtisham, Reeves Ryan Robert

机构信息

Interventional Cardiology, University of California, San Diego, California.

Interventional Cardiology and Cardiac Cath Laboratory, Sulpizio Cardiovascular Center, Division of Cardiovascular Medicine, University of California, San Diego, California.

出版信息

Catheter Cardiovasc Interv. 2016 Sep;88(3):486-9. doi: 10.1002/ccd.26166. Epub 2015 Sep 2.

Abstract

Pericardiocentesis with drain placement provides relief of symptomatic pericardial tamponade. The use of a pericardial sheath preserves access to the pericardial space in the event a drain may need to be replaced or manipulated. Although rare, sheath fracture and migration into the pericardial space may be a complication of prolonged sheath maintenance. Prompt action may allow percutaneous retrieval of the foreign body and avoid the need for surgical exploration. We report a case of successful percutaneous retrieval of a fractured pericardial sheath. © 2015 Wiley Periodicals, Inc.