文献检索文档翻译深度研究
Suppr Zotero 插件Zotero 插件
邀请有礼套餐&价格历史记录

新学期,新优惠

限时优惠:9月1日-9月22日

30天高级会员仅需29元

1天体验卡首发特惠仅需5.99元

了解详情
不再提醒
插件&应用
Suppr Zotero 插件Zotero 插件浏览器插件Mac 客户端Windows 客户端微信小程序
高级版
套餐订阅购买积分包
AI 工具
文献检索文档翻译深度研究
关于我们
关于 Suppr公司介绍联系我们用户协议隐私条款
关注我们

Suppr 超能文献

核心技术专利:CN118964589B侵权必究
粤ICP备2023148730 号-1Suppr @ 2025

Validity of (Ultra-)Short Recordings for Heart Rate Variability Measurements.

作者信息

Munoz M Loretto, van Roon Arie, Riese Harriëtte, Thio Chris, Oostenbroek Emma, Westrik Iris, de Geus Eco J C, Gansevoort Ron, Lefrandt Joop, Nolte Ilja M, Snieder Harold

机构信息

Department of Epidemiology, University of Groningen, University Medical Center Groningen, Groningen, The Netherlands.

Department of Vascular Medicine, University of Groningen, University Medical Center Groningen, Groningen, The Netherlands.

出版信息

PLoS One. 2015 Sep 28;10(9):e0138921. doi: 10.1371/journal.pone.0138921. eCollection 2015.


DOI:10.1371/journal.pone.0138921
PMID:26414314
原文链接:https://pmc.ncbi.nlm.nih.gov/articles/PMC4586373/
Abstract

OBJECTIVES: In order to investigate the applicability of routine 10s electrocardiogram (ECG) recordings for time-domain heart rate variability (HRV) calculation we explored to what extent these (ultra-)short recordings capture the "actual" HRV. METHODS: The standard deviation of normal-to-normal intervals (SDNN) and the root mean square of successive differences (RMSSD) were measured in 3,387 adults. SDNN and RMSSD were assessed from (ultra)short recordings of 10s(3x), 30s, and 120s and compared to 240s-300s (gold standard) measurements. Pearson's correlation coefficients (r), Bland-Altman 95% limits of agreement and Cohen's d statistics were used as agreement analysis techniques. RESULTS: Agreement between the separate 10s recordings and the 240s-300s recording was already substantial (r = 0.758-0.764/Bias = 0.398-0.416/d = 0.855-0.894 for SDNN; r = 0.853-0.862/Bias = 0.079-0.096/d = 0.150-0.171 for RMSSD), and improved further when three 10s periods were averaged (r = 0.863/Bias = 0.406/d = 0.874 for SDNN; r = 0.941/Bias = 0.088/d = 0.167 for RMSSD). Agreement increased with recording length and reached near perfect agreement at 120s (r = 0.956/Bias = 0.064/d = 0.137 for SDNN; r = 0.986/Bias = 0.014/d = 0.027 for RMSSD). For all recording lengths and agreement measures, RMSSD outperformed SDNN. CONCLUSIONS: Our results confirm that it is unnecessary to use recordings longer than 120s to obtain accurate measures of RMSSD and SDNN in the time domain. Even a single 10s (standard ECG) recording yields a valid RMSSD measurement, although an average over multiple 10s ECGs is preferable. For SDNN we would recommend either 30s or multiple 10s ECGs. Future research projects using time-domain HRV parameters, e.g. genetic epidemiological studies, could calculate HRV from (ultra-)short ECGs enabling such projects to be performed at a large scale.

摘要
https://cdn.ncbi.nlm.nih.gov/pmc/blobs/062d/4586373/a5cf2e241f3e/pone.0138921.g005.jpg
https://cdn.ncbi.nlm.nih.gov/pmc/blobs/062d/4586373/894ee2f02f98/pone.0138921.g001.jpg
https://cdn.ncbi.nlm.nih.gov/pmc/blobs/062d/4586373/f87888fbaf06/pone.0138921.g002.jpg
https://cdn.ncbi.nlm.nih.gov/pmc/blobs/062d/4586373/d95232f1a864/pone.0138921.g003.jpg
https://cdn.ncbi.nlm.nih.gov/pmc/blobs/062d/4586373/4c06b4784c19/pone.0138921.g004.jpg
https://cdn.ncbi.nlm.nih.gov/pmc/blobs/062d/4586373/a5cf2e241f3e/pone.0138921.g005.jpg
https://cdn.ncbi.nlm.nih.gov/pmc/blobs/062d/4586373/894ee2f02f98/pone.0138921.g001.jpg
https://cdn.ncbi.nlm.nih.gov/pmc/blobs/062d/4586373/f87888fbaf06/pone.0138921.g002.jpg
https://cdn.ncbi.nlm.nih.gov/pmc/blobs/062d/4586373/d95232f1a864/pone.0138921.g003.jpg
https://cdn.ncbi.nlm.nih.gov/pmc/blobs/062d/4586373/4c06b4784c19/pone.0138921.g004.jpg
https://cdn.ncbi.nlm.nih.gov/pmc/blobs/062d/4586373/a5cf2e241f3e/pone.0138921.g005.jpg

相似文献

[1]
Validity of (Ultra-)Short Recordings for Heart Rate Variability Measurements.

PLoS One. 2015-9-28

[2]
A Novel Smartphone App for the Measurement of Ultra-Short-Term and Short-Term Heart Rate Variability: Validity and Reliability Study.

JMIR Mhealth Uhealth. 2020-7-31

[3]
An optimization study of the ultra-short period for HRV analysis at rest and post-exercise.

J Electrocardiol. 2020

[4]
Reliability of ultrashort electrocardiographic indices in hypertension: the quest for a clinically applicable prognostic marker.

J Investig Med. 2020-2

[5]
Agreement between Ultra-Short-Term and Standard Heart Rate Variability Analysis in Resting and Post-Exercise Conditions.

Life (Basel). 2024-6-30

[6]
Reliability of Ultra-Short ECG Indices for Heart Rate Variability.

Ann Noninvasive Electrocardiol. 2011-4

[7]
Consistency of multicenter measurements of heart rate variability in survivors of acute myocardial infarction.

Pacing Clin Electrophysiol. 2000-2

[8]
Ultra-shortened time-domain HRV parameters at rest and following exercise in athletes: an alternative to frequency computation of sympathovagal balance.

Eur J Appl Physiol. 2017-11-11

[9]
Heart rate variability (HRV) in deep breathing tests and 5-min short-term recordings: agreement of ear photoplethysmography with ECG measurements, in 343 subjects.

Eur J Appl Physiol. 2016-8

[10]
Utility of using electrocardiogram measures of heart rate variability as a measure of cardiovascular autonomic neuropathy in type 1 diabetes patients.

J Diabetes Investig. 2022-1

引用本文的文献

[1]
Kinaesthetic empathy through the lens of the cinematographer: physiological and phenomenological alignments in the act of creation.

Front Neurosci. 2025-8-13

[2]
Brain activation and heart rate variability as markers of autonomic function under stress.

Sci Rep. 2025-8-1

[3]
Association between ultra-short-term heart rate variability and atrial fibrillation in heart failure population: a protocol for a prospective observational cohort study.

BMJ Open. 2025-8-1

[4]
Classifying social and physical pain from multimodal physiological signals using machine learning.

Sci Rep. 2025-7-29

[5]
Ultra-short-term heart rate variability using a photoplethysmography-based smartphone application: a TeleCheck-AF subanalysis.

Eur Heart J Digit Health. 2025-4-11

[6]
Long-term alteration of heart rate variability following childhood maltreatment: Results of a general population study.

Eur Psychiatry. 2025-6-19

[7]
Reactivity of the Autonomic Nervous System During Visual-Physical Incongruent Walking Conditions-A Virtual Reality Study.

Psychophysiology. 2025-5

[8]
Harnessing non‑invasive vagal neuromodulation: HRV biofeedback and SSP for cardiovascular and autonomic regulation (Review).

Med Int (Lond). 2025-4-29

[9]
Modulating cortical excitability and cortical arousal by pupil self-regulation.

Nat Commun. 2025-5-16

[10]
Intensive Glycemic Treatment Mitigates Cardiovascular and Mortality Risk Associated With Cardiac Autonomic Neuropathy in Type 2 Diabetes.

J Am Heart Assoc. 2025-5-6

本文引用的文献

[1]
Relation of short-term heart rate variability to incident heart failure (from the Multi-Ethnic Study of Atherosclerosis).

Am J Cardiol. 2013-5-16

[2]
Heart rate variability - a historical perspective.

Front Physiol. 2011-11-29

[3]
Association of cognitive function with albuminuria and eGFR in the general population.

Clin J Am Soc Nephrol. 2011-5-12

[4]
Reliability of Ultra-Short ECG Indices for Heart Rate Variability.

Ann Noninvasive Electrocardiol. 2011-4

[5]
Reduced autonomic flexibility as a predictor for future anxiety in girls from the general population: The TRAILS study.

Psychiatry Res. 2010-5-18

[6]
Why Bland-Altman plots should use X, not (Y+X)/2 when X is a reference method.

Stat Med. 2008-2-28

[7]
Heart rate variability: a review.

Med Biol Eng Comput. 2006-12

[8]
Repeatability of heart rate variability measures.

J Electrocardiol. 2004-7

[9]
Applying the right statistics: analyses of measurement studies.

Ultrasound Obstet Gynecol. 2003-7

[10]
Heart rate variability--a therapeutic target?

J Clin Pharm Ther. 2002-4

文献AI研究员

20分钟写一篇综述,助力文献阅读效率提升50倍

立即体验

用中文搜PubMed

大模型驱动的PubMed中文搜索引擎

马上搜索

推荐工具

医学文档翻译智能文献检索