Heart rate variability (HRV) in deep breathing tests and 5-min short-term recordings: agreement of ear photoplethysmography with ECG measurements, in 343 subjects.

作者信息

Weinschenk Stefan W, Beise Reinhard D, Lorenz Jürgen

机构信息

Department of Obstetrics and Gynecology, 4.2., Medical School, Heidelberg University, Voßstr. 2, 69115, Heidelberg, Germany.

OB/GYN Practice, Bahnhofplatz 8, 76137, Karlsruhe, Germany.

出版信息

Eur J Appl Physiol. 2016 Aug;116(8):1527-35. doi: 10.1007/s00421-016-3401-3. Epub 2016 Jun 8.


DOI:10.1007/s00421-016-3401-3
PMID:27278521
Abstract

PURPOSE: We analyzed heart rate variability (HRV) taken by ECG and photoplethysmography (PPG) to assess their agreement. We also analyzed the sensitivity and specificity of PPG to identify subjects with low HRV as an example of its potential use for clinical applications. METHODS: The HRV parameters: mean heart rate (HR), amplitude, and ratio of heart rate oscillation (E-I difference, E/I ratio), RMSSD, SDNN, and Power LF, were measured during 1-min deep breathing tests (DBT) in 343 individuals, followed by a 5-min short-term HRV (s-HRV), where the HRV parameters: HR, SD1, SD2, SDNN, Stress Index, Power HF, Power LF, Power VLF, and Total Power, were determined as well. Parameters were compared through correlation analysis and agreement analysis by Bland-Altman plots. RESULTS: PPG derived parameters HR and SD2 in s-HRV showed better agreement than SD1, Power HF, and stress index, whereas in DBT HR, E/I ratio and SDNN were superior to Power LF and RMSSD. DBT yielded stronger agreement than s-HRV. A slight overestimation of PPG HRV over HCG HRV was found. HR, Total Power, and SD2 in the s-HRV, HR, Power LF, and SDNN in the DBT showed high sensitivity and specificity to detect individuals with poor HRV. Cutoff percentiles are given for the future development of PPG-based devices. CONCLUSION: HRV measured by PPG shows good agreement with ECG HRV when appropriate parameters are used, and PPG-based devices can be employed as an easy screening tool to detect individuals with poor HRV, especially in the 1-min DBT test.

摘要

相似文献

[1]
Heart rate variability (HRV) in deep breathing tests and 5-min short-term recordings: agreement of ear photoplethysmography with ECG measurements, in 343 subjects.

Eur J Appl Physiol. 2016-8

[2]
Extraction of heart rate variability from smartphone photoplethysmograms.

Comput Math Methods Med. 2015

[3]
Accuracy Assessment of Oura Ring Nocturnal Heart Rate and Heart Rate Variability in Comparison With Electrocardiography in Time and Frequency Domains: Comprehensive Analysis.

J Med Internet Res. 2022-1-18

[4]
Comparison of HRV parameters derived from photoplethysmography and electrocardiography signals.

Annu Int Conf IEEE Eng Med Biol Soc. 2015

[5]
Ambient temperature effect on pulse rate variability as an alternative to heart rate variability in young adult.

J Clin Monit Comput. 2016-12

[6]
Assessment of heart rate variability derived from finger-tip photoplethysmography as compared to electrocardiography.

J Med Eng Technol. 2008

[7]
Multimodal Assessment of the Pulse Rate Variability Analysis Module of a Photoplethysmography-Based Telemedicine System.

Sensors (Basel). 2021-8-18

[8]
Photoplethysmography variability as an alternative approach to obtain heart rate variability information in chronic pain patient.

J Clin Monit Comput. 2015-12

[9]
Validation of Photoplethysmography Using a Mobile Phone Application for the Assessment of Heart Rate Variability in the Context of Heart Rate Variability-Biofeedback.

Psychosom Med. 2023-9-1

[10]
Comparison of pulse rate variability with heart rate variability during obstructive sleep apnea.

Med Eng Phys. 2010-10-25

引用本文的文献

[1]
Pulse rate variability as a predictor for length of stay for patients with bronchiolitis in the pediatric intensive care unit.

J Clin Monit Comput. 2025-3-25

[2]
Discussion on the comparison of Raman spectroscopy and cardiovascular disease-related imaging techniques and the future applications of Raman technology: a systematic review.

Lasers Med Sci. 2025-2-24

[3]
Heart Rate Variability, Blood Pressure and Peripheral Oxygen Saturation during Yoga and Breathing Techniques without Retention in Adult Practitioners.

J Funct Morphol Kinesiol. 2024-10-3

[4]
Frequency-Domain Features and Low-Frequency Synchronization of Photoplethysmographic Waveform Variability and Heart Rate Variability with Increasing Severity of Cardiovascular Diseases.

Biomedicines. 2024-9-12

[5]
Effect of Exercise Modality on Heart Rate Variability in Adults: A Systematic Review and Network Meta-Analysis.

Rev Cardiovasc Med. 2024-1-9

[6]
Advances in Printed Electronic Textiles.

Adv Sci (Weinh). 2024-2

[7]
Accuracy and clinical utility of heart rate variability derived from a wearable heart rate monitor in patients undergoing major abdominal surgery.

J Clin Monit Comput. 2024-4

[8]
PPG2ECGps: An End-to-End Subject-Specific Deep Neural Network Model for Electrocardiogram Reconstruction from Photoplethysmography Signals without Pulse Arrival Time Adjustments.

Bioengineering (Basel). 2023-5-23

[9]
Real-Time Evaluation of Time-Domain Pulse Rate Variability Parameters in Different Postures and Breathing Patterns Using Wireless Photoplethysmography Sensor: Towards Remote Healthcare in Low-Resource Communities.

Sensors (Basel). 2023-4-24

[10]
Processing Photoplethysmograms Recorded by Smartwatches to Improve the Quality of Derived Pulse Rate Variability.

Sensors (Basel). 2022-9-17

本文引用的文献

[1]
Validity of the Polar V800 heart rate monitor to measure RR intervals at rest.

Eur J Appl Physiol. 2016-3

[2]
Sternal pulse rate variability compared with heart rate variability on healthy subjects.

Annu Int Conf IEEE Eng Med Biol Soc. 2014

[3]
Pulse rate variability compared with Heart Rate Variability in children with and without sleep disordered breathing.

Annu Int Conf IEEE Eng Med Biol Soc. 2013

[4]
Smartphone-enabled pulse rate variability: an alternative methodology for the collection of heart rate variability in psychophysiological research.

Int J Psychophysiol. 2013-6-8

[5]
How accurate is pulse rate variability as an estimate of heart rate variability? A review on studies comparing photoplethysmographic technology with an electrocardiogram.

Int J Cardiol. 2012-7-17

[6]
A comparative study of pulse rate variability and heart rate variability in healthy subjects.

J Clin Monit Comput. 2012-2-19

[7]
Comparison of pulse rate variability with heart rate variability during obstructive sleep apnea.

Med Eng Phys. 2010-10-25

[8]
Photoplethysmography pulse rate variability as a surrogate measurement of heart rate variability during non-stationary conditions.

Physiol Meas. 2010-8-11

[9]
Respiratory stress response: a novel diagnostic method for detection of significant coronary artery disease from finger pulse wave analysis during brief respiratory exercise.

Am J Med Sci. 2010-5

[10]
An innovative noninvasive respiratory stress test indicates significant coronary artery disease.

Cardiovasc Revasc Med. 2010

文献AI研究员

20分钟写一篇综述,助力文献阅读效率提升50倍

立即体验

用中文搜PubMed

大模型驱动的PubMed中文搜索引擎

马上搜索

推荐工具

医学文档翻译智能文献检索