Suppr超能文献

[Laryngeal Tube Position Shift after Chest Compression: Comparison of Fixation Methods Using Durapore Tape, Multipore Tape, or a Neck Tape].

作者信息

Seno Hisayo, Komasawa Nobuyasu, Fujiwara Shunsuke, Miyazaki Shinichiro, Tatsumi Shinichi, Minami Toshiaki

出版信息

Masui. 2015 May;64(5):566-8.

Abstract

BACKGROUND

The laryngeal tube (LT ; Smiths Medical, Minnesota, U. S. A) is an inflatable supraglottic device for emergency airway management such as during chest compression, the instability after insertion remains a problem.

METHODS

We investigated the effectiveness of three fixation methods of LT using a manikin and automated chest compressor.

RESULTS

After 10-minute chest compression, LT without fixation was shifted by 0.4 ± 0.1 cm, which was greater than with Durapore tape (0.2 ± 0.1 cm), Multipore tape (0.2 ± 0.1 cm), or a neck tape (0.1 ± 0.1 cm). The shift of the position was smaller with neck tape fixation compared to Durapore or Multipore tape fixation.

CONCLUSIONS

A fixation neck tape may be useful in stabilizing the inserted position of LT during cardiopulmonary resuscitation.

摘要