Janssen P T, van Palenstein Helderman W H, van Aken J
Department of Biomaterials, ACTA, University of Amsterdam.
J Clin Periodontol. 1989 Jan;16(1):53-8. doi: 10.1111/j.1600-051x.1989.tb01612.x.
A device for serial radiography in maxillary and mandibular premolar and molar regions was developed. Radiographs of 9 patients were made during a period of 1 year. When testing the device, the influence of the time interval between the radiographs and the influence of the construction of the device on the reproducibility of the X-ray images were determined. An increase of the time interval between radiographs reduced the reproducibility. The use of bilateral bite blocks improved the reproducibility of the X-ray images in comparison with the images obtained with a device with a one-sided bite block. Errors in the reproducibility caused differences in the image geometry of radiographs. The in-vivo-found differences were studied for their effect on the detection threshold of observers using photographic subtraction radiography. An increase of the differences in image geometry between the radiographs resulted in a higher detection threshold and a higher % of false positive decisions. It appeared that very small differences between clinical radiographs, corresponding with an angulation error of 0.7 degrees, can be tolerated in order to prevent the occurrence of high numbers of type-I errors. The % of radiographs, which met this requirement and could be used for photographic subtraction radiography, was 55%, when taken at time intervals of 1 year.
开发了一种用于上颌和下颌前磨牙及磨牙区域的系列放射成像设备。在1年的时间里对9名患者进行了X光片拍摄。在测试该设备时,确定了X光片之间的时间间隔以及设备结构对X射线图像可重复性的影响。X光片之间时间间隔的增加会降低可重复性。与使用单侧咬块的设备所获得的图像相比,使用双侧咬块提高了X射线图像的可重复性。可重复性方面的误差导致了X光片图像几何形状的差异。研究了在体内发现的这些差异对使用摄影减影放射成像的观察者检测阈值的影响。X光片之间图像几何形状差异的增加导致更高的检测阈值和更高比例的假阳性判定。结果表明,为了防止大量I型错误的发生,临床X光片之间非常小的差异(对应0.7度的角度误差)是可以容忍的。当以1年的时间间隔拍摄时,符合这一要求且可用于摄影减影放射成像的X光片比例为55%。