Suppr超能文献

[数字化定制钢板治疗四肢复杂骨折的疗效]

[EFFECTIVENESS OF DIGITAL CUSTOMIZED STEEL PLATE IN TREATMENT OF COMPLEX FRACTURES OF LIMBS].

作者信息

Wan Yongxian, Zhuo Naiqiang, Yang Yunkang, Ge Jianhua, Lu Xiaobo

出版信息

Zhongguo Xiu Fu Chong Jian Wai Ke Za Zhi. 2015 Apr;29(4):402-5.

Abstract

OBJECTIVE

To observe the effectiveness of digital customized plate in the treatment of complex limb fracture.

METHODS

Between January 2012 and May 2013, CT raw data of complex limb fracture were used to establish the fracture three-dimensional simulation model after reduction, and a customized personalized anatomic plate was designed and used for internal fixation after open reduction in 42 cases. There were 22 males and 20 females, aged 16-53 years (average, 37.4 years). The causes of injury were traffic accident in 21 cases, falling from height in 18 cases, crush by heavy objects in 3 cases, including 26 cases of fresh closed fracture and 16 cases of open fracture (9 cases of type I and 7 cases of type II according to Gustilo classification). According to AO classification, there were 15 cases of humerus comminuted fracture, 4 cases of radial comminuted fracture, 8 cases of femoral comminuted fracture, and 15 cases of tibia comminuted fracture. The interval of injury and operation was 6-28 days (mean, 10 days).

RESULTS

Reduction and internal fixation of fracture were successfully performed on 42 patients. The length and position of digital customized plate, direction and length of screw implant, number of screw were basically identical with preoperative design. The operation time was 35-120 minutes (mean, 70 minutes); the blood loss volume was 30-500 mL (mean, 180 mL); and X ray fluoroscopy frequency was 2-6 times (mean, 3 times). Superficial infection occurred in 2 cases, and was cured after dressing change; primary healing of incision was obtained in the other patients. Forty-two cases were followed up 6-24 months with an average of 11.5 months. The fracture healing time was 8-19 weeks (mean, 14 weeks) in 41 cases; delayed union occurred in 1 case at 44 weeks after operation. The fracture anatomical reduction was achieved in 19 cases, malunion in 3 cases, and functional reduction in the other patients. At last follow-up, no plate and screw loosening and breakage was observed.

CONCLUSION

Digital customized plate in treatment of complex fractures of limbs, especially for the multiple comminuted fracture of long bones of the limbs has the advantages of convenient operation, less trauma, fewer complications, and good effectiveness.

摘要

目的

观察数字化定制钢板治疗复杂四肢骨折的疗效。

方法

2012年1月至2013年5月,利用复杂四肢骨折的CT原始数据建立复位后的骨折三维模拟模型,设计定制个性化解剖钢板,对42例患者行切开复位后使用该钢板内固定。其中男22例,女20例,年龄16 - 53岁(平均37.4岁)。受伤原因:交通事故21例,高处坠落18例,重物挤压3例;其中新鲜闭合骨折26例,开放性骨折16例(按Gustilo分类,Ⅰ型9例,Ⅱ型7例)。按AO分类,肱骨粉碎性骨折15例,桡骨粉碎性骨折4例,股骨粉碎性骨折8例,胫骨粉碎性骨折15例。受伤至手术时间为6 - 28天(平均10天)。

结果

42例患者骨折均成功复位并内固定。数字化定制钢板的长度、位置,螺钉植入方向、长度及数量与术前设计基本一致。手术时间35 - 120分钟(平均70分钟);出血量30 - 500毫升(平均180毫升);X线透视次数2 - 6次(平均3次)。2例发生浅表感染,经换药后治愈;其余患者切口均一期愈合。42例患者随访6 - 24个月,平均11.5个月。41例骨折愈合时间为8 - 19周(平均14周);1例术后44周发生延迟愈合。骨折解剖复位19例,畸形愈合3例,其余患者功能复位。末次随访时,未观察到钢板及螺钉松动、断裂。

结论

数字化定制钢板治疗四肢复杂骨折,尤其对于四肢长骨多发粉碎性骨折,具有操作方便、创伤小、并发症少、疗效好等优点。