To investigate the validity of a computer-based method using temporal subtraction in carpal joints of patients with rheumatoid arthritis (RA), which can detect the difference in joint space between two images with the joint space difference index (JSDI).
The study consisted of 43 patients with RA (39 females and 4 males) who underwent radiography at baseline and at 1-year follow-up. The joint space narrowing (JSN) of carpal joints on bilateral hand radiographs was assessed by our computer-based method, using the Sharp/van der Heijde method as the standard of reference. We compared the JSDI of joints with JSN progression in the follow-up period with that of those without JSN progression. In addition, we examined whether there is a significant difference in JSDI in terms of laterality or topology of the joint.
The JSDI of joints with JSN progression was significantly higher than that of those without JSN progression (Mann-Whitney U test, p < 0.001). There was no statistically significant difference in the JSDI between the left and right carpal joints, which was analysed for five different joints altogether and each joint separately (Mann-Whitney U test, p > 0.05). There was statistically significant difference in JSDI among different joints (Kruskal-Wallis test, p = 0.003).
These results suggest that our computer-based method may be useful to recognize the JSN progression on radiographs of rheumatoid wrists.
The computer-based temporal subtraction method can detect the JSN progression in the wrist, which is the single most commonly involved site in RA.
研究一种基于计算机的时间减法方法在类风湿关节炎(RA)患者腕关节中的有效性,该方法可通过关节间隙差异指数(JSDI)检测两张图像之间的关节间隙差异。
本研究纳入43例RA患者(39例女性,4例男性),在基线和1年随访时进行了X线摄影。采用基于计算机的方法评估双侧手部X线片上腕关节的关节间隙变窄(JSN)情况,并以Sharp/van der Heijde方法作为参考标准。我们比较了随访期间有JSN进展的关节与无JSN进展的关节的JSDI。此外,我们还研究了关节的左右侧别或拓扑结构在JSDI方面是否存在显著差异。
有JSN进展的关节的JSDI显著高于无JSN进展的关节(Mann-Whitney U检验,p < 0.001)。对总共五个不同关节以及每个关节分别进行分析,左右腕关节之间的JSDI无统计学显著差异(Mann-Whitney U检验,p > 0.05)。不同关节之间的JSDI存在统计学显著差异(Kruskal-Wallis检验,p = 0.003)。
这些结果表明,我们基于计算机的方法可能有助于识别类风湿性腕关节X线片上的JSN进展情况。
基于计算机的时间减法方法可以检测腕关节中的JSN进展,腕关节是RA中最常受累的单一部位。