Suppr超能文献

一家大都市三级医院成人及儿科CT检查的资金来源:医疗保险统计数据实际涵盖了多少?

Sources of funding for adult and paediatric CT procedures at a metropolitan tertiary hospital: How much do Medicare statistics really cover?

作者信息

Hayton Anna, Wallace Anthony, Johnston Peter

机构信息

Medical Imaging Section, Australian Radiation Protection and Nuclear Safety Agency, Melbourne, Victoria, Australia.

出版信息

J Med Imaging Radiat Oncol. 2015 Dec;59(6):695-701. doi: 10.1111/1754-9485.12392. Epub 2015 Oct 27.

Abstract

INTRODUCTION

The radiation dose to the Australian paediatric population as a result of medical imaging is of growing concern, in particular the dose from CT. Estimates of the Australian population dose have largely relied on Medicare Australia statistics, which capture only a fraction of those imaging procedures actually performed. The fraction not captured has been estimated using a value obtained for a survey of the adult population in the mid-1990s. To better quantify the fraction of procedures that are not captured by Medicare Australia, procedure frequency and funding data for adult and paediatric patients were obtained from a metropolitan tertiary teaching and research hospital.

METHODS

Five calendar years of data were obtained with a financial class specified for each individual procedure. The financial classes were grouped to give the percentage of Medicare Australia billable procedures for both adult and paediatric patients. The data were also grouped to align with the Medicare Australia age cohorts.

RESULTS

The percentage of CT procedures billable to Medicare Australia increased from 16% to 28% between 2008 and 2012. In 2012, the percentage billable for adult and paediatric patients was 28% and 33%, respectively; however, many adult CT procedures are performed at stand-alone clinics, which bulk bill.

CONCLUSION

Using Medicare Australia statistics alone, the frequency of paediatric CT procedures performed on the Australian paediatric population will be grossly under estimated. A correction factor of 4.5 is suggested for paediatric procedures and 1.5 for adult procedures. The fraction of actual procedures performed that are captured by Medicare Australia will vary with time.

摘要

引言

医学成像给澳大利亚儿科人群带来的辐射剂量日益受到关注,尤其是CT扫描的剂量。对澳大利亚人群剂量的估计很大程度上依赖于澳大利亚医疗保险统计数据,而这些数据仅涵盖了实际进行的成像检查中的一部分。未涵盖的部分是根据20世纪90年代中期对成年人群体调查得出的值进行估算的。为了更好地量化澳大利亚医疗保险未涵盖的检查比例,我们从一家大都市三级教学和研究医院获取了成人和儿科患者的检查频率及费用数据。

方法

获取了五个日历年的数据,并为每个单独的检查指定了财务类别。这些财务类别被分组,以得出澳大利亚医疗保险可计费检查在成人和儿科患者中的百分比。数据还按照澳大利亚医疗保险的年龄组进行了分组。

结果

2008年至2012年间,澳大利亚医疗保险可计费的CT检查比例从16%增至28%。2012年,成人和儿科患者的可计费比例分别为28%和33%;然而,许多成人CT检查是在提供批量计费服务的独立诊所进行的。

结论

仅使用澳大利亚医疗保险统计数据,澳大利亚儿科人群接受儿科CT检查的频率将被严重低估。建议儿科检查的校正因子为4.5,成人检查为1.5。澳大利亚医疗保险涵盖的实际检查比例会随时间变化。

文献检索

告别复杂PubMed语法,用中文像聊天一样搜索,搜遍4000万医学文献。AI智能推荐,让科研检索更轻松。

立即免费搜索

文件翻译

保留排版,准确专业,支持PDF/Word/PPT等文件格式,支持 12+语言互译。

免费翻译文档

深度研究

AI帮你快速写综述,25分钟生成高质量综述,智能提取关键信息,辅助科研写作。

立即免费体验