Institute of Food Safety, Animal Health and Environment "BIOR", Lejupes iela 3, Riga, LV-1076, Latvia.
Institute of Food Safety, Animal Health and Environment "BIOR", Lejupes iela 3, Riga, LV-1076, Latvia; University of Latvia, Department of Chemistry, Kr. Valdemara iela 48, Riga, LV-1013, Latvia.
Anal Chim Acta. 2015 Oct 22;898:60-72. doi: 10.1016/j.aca.2015.10.008. Epub 2015 Oct 20.
A new analytical method was established and validated for the analysis of 27 brominated flame retardants (BFRs), including so called "emerging" and "novel" BFRs (EBFRs and NBFRs) in fish samples. High performance liquid chromatography (HPLC) coupled to Orbitrap mass spectrometry (Orbitrap-MS) employing atmospheric pressure photoionization (APPI) interface operated in negative mode was used for the identification/quantitation of contaminants. HPLC-Orbitrap-MS analysis provided a fast separation of selected analytes within 14 min, thus demonstrating a high throughput processing of samples. The developed methodology was tested by intralaboratory validation in terms of recovery, repeatability, linear calibration ranges, instrumental and method limits of quantitation (i-LOQ and m-LOQ), and where possible, trueness was verified by analysis of certified reference materials (CRMs). Recoveries of analytes were between 80 and 119%, while the repeatability in terms of relative standard deviations (RSDs) was in the range from 1.2 to 15.5%. The measured values for both analyzed CRMs agreed with the provided consensus values, revealing the recovery of reference concentrations in 72-119% range. The elaborated method met the sensitivity criterion according to Commission Recommendation 2014/118/EU on monitoring of BFRs in food products for majority of the compounds. The concentrations of polybrominated diphenyl ethers (PBDEs) in real samples determined by HPLC-APPI-Orbitrap-MS method and validated gas chromatography-high-resolution mass spectrometry (GC-HRMS) method were found to be in a good agreement.
建立并验证了一种新的分析方法,用于分析鱼类样品中的 27 种溴系阻燃剂(BFRs),包括所谓的“新兴”和“新型”BFRs(EBFRs 和 NBFRs)。采用大气压光电离(APPI)接口的高效液相色谱(HPLC)-轨道阱质谱(Orbitrap-MS)在负离子模式下用于污染物的鉴定/定量。HPLC-Orbitrap-MS 分析在 14 分钟内快速分离选定的分析物,从而证明了样品的高通量处理。该方法通过实验室内部验证进行了测试,包括回收率、重复性、线性校准范围、仪器和方法定量限(i-LOQ 和 m-LOQ),并且在可能的情况下,通过分析认证参考物质(CRMs)验证了准确度。分析物的回收率在 80%至 119%之间,而相对标准偏差(RSDs)的重复性在 1.2%至 15.5%之间。对两种分析 CRM 的测量值与提供的共识值相符,表明参考浓度的回收率在 72%至 119%的范围内。根据欧盟委员会 2014/118/EU 关于食品中 BFRs 监测的建议,该方法满足大多数化合物的灵敏度标准。通过 HPLC-APPI-Orbitrap-MS 方法和经过验证的气相色谱-高分辨率质谱(GC-HRMS)方法测定的多溴联苯醚(PBDEs)的实际样品浓度之间存在良好的一致性。