Levine Judah
IEEE Trans Ultrason Ferroelectr Freq Control. 2016 Apr;63(4):561-70. doi: 10.1109/TUFFC.2015.2495014. Epub 2015 Oct 27.
A method is presented for synchronizing the time of a clock to a remote time standard when the channel connecting the two has significant delay variation that can be described only statistically. The method compares the Allan deviation of the channel fluctuations to the free-running stability of the local clock, and computes the optimum interval between requests based on one of the three selectable requirements: 1) choosing the highest possible accuracy; 2) choosing the best tradeoff of cost versus accuracy; or 3) minimizing the number of requests to realize a specific accuracy. Once the interval between requests is chosen, the final step is to steer the local clock based on the received data. A typical adjustment algorithm, which supports both the statistical considerations based on the Allan deviation comparison and the timely detection of errors, is included as an example.
提出了一种方法,用于在连接两者的通道存在显著延迟变化(只能用统计方法描述)时,将时钟时间与远程时间标准同步。该方法将通道波动的阿伦偏差与本地时钟的自由运行稳定性进行比较,并根据三个可选要求之一计算请求之间的最佳间隔:1)选择尽可能高的精度;2)选择成本与精度的最佳权衡;或3)最小化实现特定精度所需的请求数量。一旦选择了请求之间的间隔,最后一步就是根据接收到的数据调整本地时钟。作为示例,包含了一种典型的调整算法,该算法既支持基于阿伦偏差比较的统计考虑,又支持对错误的及时检测。