The purpose of this study was to test the accuracy of a single synovial fluid biomarker, α-defensin, in diagnosing periprosthetic joint infection in revision total hip and revision total knee arthroplasty.
A total of 102 patients comprising 116 revision total hip arthroplasty and revision total knee arthroplasty procedures performed between May 2013 and March 2014 were prospectively evaluated. Cases were categorized as infected or notinfected using Musculoskeletal Infection Society criteria. Synovial fluid was obtained and tested for α-defensin using a commercially available kit (Synovasure [CD Diagnostics, Baltimore, Maryland]).
For first-stage and single-stage revisions, the α-defensin test had a sensitivity of 100% (95% confidence interval [CI], 86%-100%) and a specificity of 98% (95% CI, 90%-100%) with a positive predictive value of 96% (95% CI, 80%-99%) and negative predictive value of 100% (95% CI, 93%-100%).
A positive α-defensin test result was significantly more sensitive and specific for predicting infection than current diagnostic testing and should be considered when managing periprosthetic joint infection.
Level III, Study of Diagnostic Test.
本研究的目的是测试单一滑液生物标志物α-防御素在诊断翻修全髋关节置换术和翻修全膝关节置换术中假体周围感染的准确性。
前瞻性评估了2013年5月至2014年3月期间进行的102例患者的116例翻修全髋关节置换术和翻修全膝关节置换术。根据肌肉骨骼感染学会标准将病例分为感染或未感染。获取滑液并使用市售试剂盒(Synovasure [CD Diagnostics,巴尔的摩,马里兰州])检测α-防御素。
对于一期和单期翻修,α-防御素检测的敏感性为100%(95%置信区间[CI],86%-100%),特异性为98%(95%CI,90%-100%),阳性预测值为96%(95%CI,80%-99%),阴性预测值为100%(95%CI,93%-100%)。
α-防御素检测结果为阳性在预测感染方面比当前诊断检测更敏感且更具特异性,在处理假体周围感染时应予以考虑。
III级,诊断试验研究。