Tjan A H, Chiu J
Loma Linda University, School of Dentistry, Calif.
J Prosthet Dent. 1989 Jun;61(6):659-64. doi: 10.1016/s0022-3913(89)80037-x.
This study evaluated the microleakage patterns of complete cast-gold crowns cemented onto teeth rebuilt with pin-retained cores made from cast gold, amalgam, composite resin, and silver-reinforced glass ionomer by using three different cements (zinc phosphate, glass ionomer, and resin cement). Crowns cemented onto unrebuilt tooth preparations with zinc phosphate cement served as controls. The cemented specimens were thermocycled between 4 degrees and 50 degrees C in waterbaths. They were then embedded in epoxy resin and sectioned. The extent of marginal microleakage was evaluated with a stereomicroscope and scored. The findings indicated that the type of luting agent used appeared to affect microleakage more than the core material. No significant differences in the degree of microleakage were found under crowns cemented onto teeth rebuilt with the four core materials when cemented with the same luting cement.