Suppr超能文献

肿瘤与正常前列腺组织表观弥散系数比值作为一种量化前列腺弥散加权成像的方法。

Ratio of Tumor to Normal Prostate Tissue Apparent Diffusion Coefficient as a Method for Quantifying DWI of the Prostate.

机构信息

1 Department of Radiology, Addenbrooke's Hospital and the University of Cambridge, Hills Rd, Cambridge, CB2 0QQ, UK.

2 Department of Epidemiology and Biostatistics, Memorial Sloan Kettering Cancer Center, New York, NY.

出版信息

AJR Am J Roentgenol. 2015 Dec;205(6):W585-93. doi: 10.2214/AJR.15.14338.

Abstract

OBJECTIVE

The purpose of this study was to investigate the ability of the apparent diffusion coefficient (ADC) ratio of tumor to normal prostate tissue to overcome inherent variability based on choice of b values, with whole-mount histopathologic analysis as the reference standard for tumor identification.

MATERIALS AND METHODS

Thirty-nine patients with prostate cancer underwent 3-T MRI, including DWI with b values of 0, 150, 750, and 1000 s/mm(2). ADC maps were derived from four b value combinations. Histologically derived ROIs were defined for prostate tumor and benign prostate tissue to generate a ratio. The concordance correlation coefficient was used to evaluate agreement and reproducibility at different b values. Bland-Altman plots were used to evaluate the pattern of relative measurement difference between b value combinations. The relationship between ADC values and Gleason score was tested by Spearman rank correlation.

RESULTS

ADC values varied depending on the b value combination selected. The concordance correlation coefficient was higher for ADC ratios (0.883; 95% CI, 0.816-0.927) compared with absolute ADC values for normal tissue (0.873; 95% CI, 0.799-0.921) and tumor (0.792; 95% CI, 0.688-0.864). The ADC ratio concordance correlation coefficient for transition zone tumors was considerably higher than that for the peripheral zone in all cases. Bland-Altman analysis showed higher variation for ADC maps incorporating a b value of zero for both ratio and absolute values. There was a stronger inverse relationship to Gleason score for ADC ratios (rho, -0.354 to -0.456) compared with absolute ADC values (rho, -0.117 to -0.379).

CONCLUSION

The use of a simple ratio of prostate tumor ADC to normal tissue ADC improved the concordance between different b value combinations and could provide a more robust means of assessing restricted diffusion in the prostate.

摘要

目的

本研究旨在探讨肿瘤与正常前列腺组织的表观扩散系数(ADC)比值是否能够克服基于 b 值选择的固有变异性,以全器官病理分析作为肿瘤识别的参考标准。

材料与方法

39 例前列腺癌患者接受 3-T MRI 检查,包括 b 值为 0、150、750 和 1000 s/mm²的 DWI。从四个 b 值组合中得出 ADC 图。根据组织学来源,为前列腺肿瘤和良性前列腺组织定义 ROI,以生成比值。使用一致性相关系数评估不同 b 值下的一致性和可重复性。Bland-Altman 图用于评估 b 值组合之间相对测量差异的模式。使用 Spearman 秩相关检验 ADC 值与 Gleason 评分之间的关系。

结果

ADC 值取决于所选的 b 值组合。与正常组织(0.873;95%CI,0.799-0.921)和肿瘤(0.792;95%CI,0.688-0.864)的绝对 ADC 值相比,ADC 比值的一致性相关系数更高(0.883;95%CI,0.816-0.927)。在所有情况下,移行区肿瘤的 ADC 比值一致性相关系数都明显高于外周区。Bland-Altman 分析显示,对于比值和绝对值,包含 b 值为零的 ADC 图变化较大。与绝对 ADC 值(rho,-0.117 至-0.379)相比,ADC 比值与 Gleason 评分之间呈更强的负相关关系(rho,-0.354 至-0.456)。

结论

使用肿瘤 ADC 与正常组织 ADC 的简单比值可以提高不同 b 值组合之间的一致性,为评估前列腺内受限扩散提供更可靠的方法。