Suppr超能文献

使用自门控心脏电影磁共振成像和k-t稀疏灵敏度编码技术评估冠状动脉内皮功能

Coronary endothelial function assessment using self-gated cardiac cine MRI and k-t sparse SENSE.

作者信息

Yerly Jérôme, Ginami Giulia, Nordio Giovanna, Coristine Andrew J, Coppo Simone, Monney Pierre, Stuber Matthias

机构信息

Department of Radiology, University Hospital and University of Lausanne, Lausanne, Switzerland.

Center for Biomedical Imaging, Lausanne, Switzerland.

出版信息

Magn Reson Med. 2016 Nov;76(5):1443-1454. doi: 10.1002/mrm.26050. Epub 2015 Nov 24.

Abstract

PURPOSE

Electrocardiogram (ECG)-gated cine MRI, paired with isometric handgrip exercise, can be used to accurately, reproducibly, and noninvasively measure coronary endothelial function (CEF). Obtaining a reliable ECG signal at higher field strengths, however, can be challenging due to rapid gradient switching and an increased heart rate under stress. To address these limitations, we present a self-gated cardiac cine MRI framework for CEF measurements that operates without ECG signal.

METHODS

Cross-sectional slices of the right coronary artery (RCA) were acquired using a two-dimensional golden angle radial trajectory. This sampling approach, combined with the k-t sparse SENSE algorithm, allows for the reconstruction of both real-time images for self-gating signal calculations and retrospectively reordered self-gated cine images. CEF measurements were quantitatively compared using both the self-gated and the standard ECG-gated approach.

RESULTS

Self-gated cine images with high-quality, temporal, and spatial resolution were reconstructed for 18 healthy volunteers. CEF as measured in self-gated images was in good agreement (R  = 0.60) with that measured by its standard ECG-gated counterpart.

CONCLUSION

High spatial and temporal resolution cross-sectional cine images of the RCA can be obtained without ECG signal. The coronary vasomotor response to handgrip exercise compares favorably with that obtained with the standard ECG-gated method. Magn Reson Med 76:1443-1454, 2015. © 2015 International Society for Magnetic Resonance in Medicine.

摘要

目的

心电图(ECG)门控电影磁共振成像(MRI)结合等长握力运动,可用于准确、可重复且无创地测量冠状动脉内皮功能(CEF)。然而,在较高场强下获得可靠的ECG信号可能具有挑战性,这是由于快速的梯度切换以及应激状态下心率增加所致。为解决这些限制,我们提出一种用于CEF测量的自门控心脏电影MRI框架,该框架无需ECG信号即可运行。

方法

使用二维黄金角径向轨迹采集右冠状动脉(RCA)的横断面图像。这种采样方法与k-t稀疏灵敏度编码(SENSE)算法相结合,能够重建用于自门控信号计算的实时图像以及回顾性重新排序的自门控电影图像。使用自门控和标准ECG门控方法对CEF测量进行定量比较。

结果

为18名健康志愿者重建了具有高质量、时间和空间分辨率的自门控电影图像。自门控图像中测量的CEF与其标准ECG门控对应图像中测量的结果具有良好的一致性(R = 0.60)。

结论

无需ECG信号即可获得RCA的高空间和时间分辨率横断面电影图像。握力运动引起的冠状动脉血管舒缩反应与标准ECG门控方法获得的结果相当。《磁共振医学》76:1443 - 1454, 2015。© 2015国际磁共振医学学会。