A quick and simple ultra-high performance supercritical fluid chromatography-photodiode array detector method was developed and validated for the simultaneous determination of 9 carotenoids in dietary supplements. The influences of stationary phase, co-solvent, pressure, temperature and flow rate on the separation of carotenoids were evaluated. The separation of the carotenoids was carried out using an Acquity UPC(2) HSS C18 SB column (150mm×3.0mm, 1.8μm) by gradient elution with carbon dioxide and a 1:2 (v:v) methanol/ethanol mixture. The column temperature was set to 35°C and the backpressure was 15.2MPa. Under these conditions, 9 carotenoids and the internal standard, β-apo-8'-carotenal, were successfully separated within 10min. The correlation coefficients (R(2)) of the calibration curves were all above 0.997, the limits of detection for the 9 carotenoids were in the range of 0.33-1.08μg/mL, and the limits of quantification were in the range of 1.09-3.58μg/mL. The mean recoveries were from 93.4% to 109.5% at different spiking levels, and the relative standard deviations were between 0.8% and 6.0%. This method was successfully applied to the determination of 9 carotenoids in commercial dietary supplements.

摘要

建立并验证了一种快速简便的超高效超临界流体色谱 - 光电二极管阵列检测法,用于同时测定膳食补充剂中的9种类胡萝卜素。评估了固定相、共溶剂、压力、温度和流速对类胡萝卜素分离的影响。使用Acquity UPC(2) HSS C18 SB柱(150mm×3.0mm,1.8μm),通过二氧化碳与1:2(v:v)甲醇/乙醇混合物的梯度洗脱进行类胡萝卜素的分离。柱温设定为35°C,背压为15.2MPa。在这些条件下,9种类胡萝卜素和内标β-阿朴-8'-胡萝卜醛在10分钟内成功分离。校准曲线的相关系数(R(2))均高于0.997,9种类胡萝卜素的检测限在0.33 - 1.08μg/mL范围内,定量限在1.09 - 3.58μg/mL范围内。在不同加标水平下,平均回收率为93.4%至109.5%,相对标准偏差在0.8%至6.0%之间。该方法成功应用于商业膳食补充剂中9种类胡萝卜素的测定。

文献检索

告别复杂PubMed语法,用中文像聊天一样搜索,搜遍4000万医学文献。AI智能推荐,让科研检索更轻松。

立即免费搜索

文件翻译

保留排版,准确专业,支持PDF/Word/PPT等文件格式,支持 12+语言互译。

免费翻译文档

深度研究

AI帮你快速写综述,25分钟生成高质量综述,智能提取关键信息,辅助科研写作。

立即免费体验