McCreesh Karen M, Anjum Shakeel, Crotty James M, Lewis Jeremy S
Department of Clinical Therapies, University of Limerick, Limerick, Ireland.
Department of Rheumatology, University Hospital Limerick, Limerick, Ireland.
J Clin Ultrasound. 2016 Mar-Apr;44(3):159-66. doi: 10.1002/jcu.22318. Epub 2015 Dec 15.
Rotator cuff (RC) tendinopathy has been widely ascribed to impingement of the supraspinatus tendon (SsT) in the subacromial space, measured as the acromiohumeral distance (AHD). Ultrasound (US) is suitable for measuring AHD and SsT thickness, but few reliability studies have been carried out in symptomatic populations, and interrater reliability is unconfirmed. This study aimed to examine the intrarater and interrater reliability of US measurements of AHD and SsT thickness in asymptomatic control subjects and patients with RC tendinopathy.
Seventy participants were recruited and grouped as healthy controls (n = 25) and RC tendinopathy (n = 45). Repeated US measurements of AHD and SsT thickness were obtained by one rater in both groups and by two raters in the RC tendinopathy group.
Intrarater and interrater reliability coefficients were excellent for both measurements (intraclass correlation > 0.92), but the intrarater reliability was superior. The minimal detectable change values in the symptomatic group were 0.7 mm for AHD and 0.6 mm for SsT thickness for a single experienced examiner; the values rose to 1.2 mm and 1.3 mm, respectively, for the pair of examiners.
The results support the reliability of US for the measurement of AHD and SsT thickness in patients with symptomatic RC tendinopathy and provide minimal detectable change values for use in future research studies.
肩袖(RC)肌腱病广泛归因于肩峰下间隙中冈上肌腱(SsT)的撞击,通过肩峰肱骨距离(AHD)来衡量。超声(US)适用于测量AHD和SsT厚度,但针对有症状人群的可靠性研究较少,且不同评估者间的可靠性尚未得到证实。本研究旨在检验在无症状对照受试者和RC肌腱病患者中,US测量AHD和SsT厚度的评估者内和评估者间可靠性。
招募了70名参与者,分为健康对照组(n = 25)和RC肌腱病组(n = 45)。两组均由一名评估者对AHD和SsT厚度进行重复的US测量,RC肌腱病组还由两名评估者进行测量。
两种测量的评估者内和评估者间可靠性系数均极佳(组内相关> 0.92),但评估者内可靠性更优。对于一名经验丰富的检查者,有症状组中AHD的最小可检测变化值为0.7 mm,SsT厚度为0.6 mm;对于两名检查者,相应值分别升至1.2 mm和1.3 mm。
结果支持US在测量有症状RC肌腱病患者的AHD和SsT厚度方面的可靠性,并提供了最小可检测变化值以供未来研究使用。