Hougs Kjær Birgitte, Ellegaard Karen, Wieland Ina, Warming Susan, Juul-Kristensen Birgit
a Department of Physical and Occupational Therapy , Bispebjerg and Frederiksberg University Hospitals , Copenhagen , Denmark.
b Department of Rheumatology , Copenhagen University Hospital , Frederiksberg , Copenhagen , Denmark.
Physiother Theory Pract. 2017 May;33(5):398-409. doi: 10.1080/09593985.2017.1318419. Epub 2017 May 8.
US-examinations related to shoulder impingement (SI) often vary due to methodological differences, examiner positions, transducers, and recording parameters. Reliable US protocols for examination of different structures related to shoulder impingement are therefore needed.
To investigate the intra- and inter-rater reliability of the existing ultrasound (US) examinations of the subacromial space, the subacromial-subdeltoid bursa, and the supraspinatus tendon.
In a three-phased design, two physiotherapists using a standardized US protocol examined the thickness of the supraspinatus tendon (SUPRA) and subacromial subdeltoid (SASD) bursa in two imaging positions, and the acromial humeral distance (AHD) in one position. Additionally, agreement on dynamic impingement (DI) examination was performed. The intra- and inter-rater reliability was carried out on the same day.
Forty-six sports active participants with a mean age of 37 years (range 18-57) participated. Twenty-two had SI and pain within previous week and 24 did not have SI or pain within previous week.
Intra- and inter-rater reliability ICC (2,3) models were all above 0.80 (range 0.82-0.99) with no systematic bias (Bland Altman plots). For the DI examination, the overall agreement was 98% and 93%, with Kappa of 0.96 and 0.82, for intra- and inter-rater reliability, respectively.
The reliability of the current standardized protocol for US examination of SI was excellent and considered feasible for clinical practice.
由于方法差异、检查者位置、换能器和记录参数的不同,与肩部撞击症(SI)相关的超声检查结果常常存在差异。因此,需要可靠的超声检查方案来检查与肩部撞击症相关的不同结构。
研究肩峰下间隙、肩峰下 - 三角肌下滑囊和冈上肌腱现有超声检查在评估者内和评估者间的可靠性。
采用三阶段设计,两名物理治疗师使用标准化超声检查方案,在两个成像位置检查冈上肌腱(SUPRA)和肩峰下三角肌下滑囊(SASD)的厚度,在一个位置检查肩峰肱骨距离(AHD)。此外,还对动态撞击症(DI)检查的一致性进行了评估。评估者内和评估者间的可靠性在同一天进行。
46名运动活跃参与者,平均年龄37岁(范围18 - 57岁)。其中22人在过去一周内有肩部撞击症和疼痛,24人在过去一周内没有肩部撞击症或疼痛。
评估者内和评估者间可靠性的ICC(2,3)模型均高于0.80(范围0.82 - 0.99),且无系统偏差(Bland Altman图)。对于DI检查,评估者内和评估者间可靠性的总体一致性分别为98%和93%,Kappa值分别为0.96和0.82。
目前用于肩部撞击症超声检查的标准化方案可靠性极佳,临床实践中可行。