Suppr超能文献

使用自调式锉预备椭圆形根管后根管充填质量的放射学、体视学和显微镜评估

Radiological, stereological, and microscopic evaluation of the quality of canal fillings in oval-shaped root canals prepared with self-adjusting file.

作者信息

Uzunoglu Emel, Ilgın Can, Yuruker Sinan, Görduysus Melahat

机构信息

Department of Endodontics, Faculty of Dentistry, Hacettepe University, Ankara, Turkey.

Department of Histology and Embryology, Faculty of Medicine, Hacettepe University, Ankara, Turkey.

出版信息

Scanning. 2016 Sep;38(5):427-433. doi: 10.1002/sca.21289. Epub 2015 Dec 23.

Abstract

The aim of this study was to evaluate the quality of the canal fillings performed by thermoplastic technique (Herofill) and cold lateral condensation (CLC) techniques in oval shaped canals following self-adjusting file (SAF) preparation using radiological, stereological, and microscopic evaluation methods. Twelve pairs of oval-shaped root canals were prepared with SAF and filled using CLC (n = 12) or the Herofill system (n = 12). The quality of the root canal filling was evaluated by (i) scoring bidirectional storage phosphor plate images, (ii) stereological (volumetric) analysis of cone beam computerized tomography (CBCT) images, and (iii) microscopic analysis of the cross-sectioned area of the canal and gutta-percha via image analysis software. Chi-square test, t-test, and Mann-Whitney U-tests were used respectively (p < 0.05) for the aforementioned evaluations. 58.33% of the fillings (total n = 24) that were found to be sufficient in a bucco-lingual (BL) projection were considered insufficient in the mesio-distal (MD) projection according to radiological scoring. The difference in the findings between the two types of projections (BL and MD) was significant (p < 0.05). The results of the stereological evaluation of CBCT images and image analysis of cross-sections showed no statistically significant difference between the CLC and Herofill (p > 0.05). Herofill was not superior to cold lateral compaction. Stereology can be used to obtain unbiased information about the volume of root canal fillings. Both filling techniques failed to achieve the desirable goal of 0% empty volume in all of the cases and all evaluation systems confirmed this result. SCANNING 38:427-433, 2016. © 2015 Wiley Periodicals, Inc.

摘要

本研究旨在采用放射学、体视学和显微镜评估方法,评价在使用自调式锉(SAF)预备椭圆形根管后,热塑性技术(HeroFill)和冷侧方加压(CLC)技术进行根管充填的质量。用SAF预备12对椭圆形根管,并用CLC(n = 12)或HeroFill系统(n = 12)进行充填。通过以下方法评估根管充填质量:(i)对双向存储磷光板图像评分;(ii)对锥形束计算机断层扫描(CBCT)图像进行体视学(体积)分析;(iii)通过图像分析软件对根管和牙胶的横截面区域进行显微镜分析。上述评估分别采用卡方检验、t检验和曼-惠特尼U检验(p < 0.05)。根据放射学评分,在颊舌(BL)投照中被认为充足的充填物(总数n = 24)中,58.33%在近远中(MD)投照中被认为不足。两种投照类型(BL和MD)的结果差异有统计学意义(p < 0.05)。CBCT图像的体视学评估结果和横截面图像分析显示,CLC和HeroFill之间无统计学显著差异(p > 0.05)。HeroFill并不优于冷侧方加压。体视学可用于获取关于根管充填物体积的无偏信息。两种充填技术在所有病例中均未达到理想的0%空体积目标,所有评估系统均证实了这一结果。《扫描》38:427 - 433,2016年。© 2015威利期刊公司

文献检索

告别复杂PubMed语法,用中文像聊天一样搜索,搜遍4000万医学文献。AI智能推荐,让科研检索更轻松。

立即免费搜索

文件翻译

保留排版,准确专业,支持PDF/Word/PPT等文件格式,支持 12+语言互译。

免费翻译文档

深度研究

AI帮你快速写综述,25分钟生成高质量综述,智能提取关键信息,辅助科研写作。

立即免费体验