Suppr超能文献

一种将支气管内渡边栓子置入支气管的新技术:侧抓法。

A Novel Technique for the Placement of Endobronchial Watanabe Spigots Into the Bronchus: Side-Grasping Method.

作者信息

Kida Hirotaka, Muraoka Hiromi, Inoue Takeo, Mineshita Masamichi, Kurimoto Noriaki, Miyazawa Teruomi

机构信息

Departments of *Internal Medicine †Respiratory Surgery, Division of Respiratory and Infectious Diseases, St. Marianna University School of Medicine, Kawasaki, Japan.

出版信息

J Bronchology Interv Pulmonol. 2016 Jan;23(1):71-5. doi: 10.1097/LBR.0000000000000213.

Abstract

BACKGROUND

Bronchial occlusion with an endobronchial Watanabe spigot (EWS) is effective for the management of persistent pulmonary air leaks; however, an optimal procedure for placing the spigot at the target bronchus remains debatable. The procedure most currently applied involves grasping the middle of the graspable part of the EWS with grasping forceps (conventional method). In this study, we assess a new technique, the side-grasping method, to maneuver the spigot into the target bronchus by using rotatable biopsy forceps to grasp the edge of the graspable part of the EWS. The aim of this study is to evaluate the effectiveness of this new technique for the simple placement of the EWS.

METHODS

To compare the number of bronchoscopists who were able to place the EWS correctly within 10 minutes, and the time needed to place each spigot for both methods into 4 canine bronchi.

RESULTS

More bronchoscopists correctly placed the EWS within 10 minutes using the side-grasping method compared with the conventional method (35/40 vs. 15/40, P<0.01). The total time needed to place spigots into all bronchi using the side-grasping method was 13±2.2 minutes versus 27.8±3.6 minutes using the conventional method (P<0.01).

CONCLUSION

The side-grasping method described in this study was a simple and effective technique for correctly placing an EWS spigot into the target bronchus.

摘要

背景

使用支气管内渡边栓子(EWS)进行支气管封堵对于持续性肺漏气的处理是有效的;然而,将栓子放置在目标支气管的最佳操作方法仍存在争议。目前最常用的方法是用抓取钳夹住EWS可抓取部分的中间(传统方法)。在本研究中,我们评估一种新技术,即侧抓法,通过使用可旋转活检钳抓住EWS可抓取部分的边缘,将栓子 maneuver 到目标支气管中。本研究的目的是评估这种新技术在简单放置EWS方面的有效性。

方法

比较两种方法在4只犬的支气管中,能够在10分钟内正确放置EWS的支气管镜医师数量,以及放置每个栓子所需的时间。

结果

与传统方法相比,使用侧抓法在10分钟内正确放置EWS的支气管镜医师更多(35/40对15/40,P<0.01)。使用侧抓法将栓子放置到所有支气管所需的总时间为13±2.2分钟,而使用传统方法为27.8±3.6分钟(P<0.01)。

结论

本研究中描述的侧抓法是一种将EWS栓子正确放置到目标支气管的简单有效的技术。

文献AI研究员

20分钟写一篇综述,助力文献阅读效率提升50倍。

立即体验

用中文搜PubMed

大模型驱动的PubMed中文搜索引擎

马上搜索

文档翻译

学术文献翻译模型,支持多种主流文档格式。

立即体验