Judas Fernando M, Ferreira Joana Fonseca, Dias Rui Freitas, Lucas Francisco M
Orthopedics Department, Centro Hospitalar e Universitário de Coimbra (CHUC), Faculty of Medicine, University of Coimbra, Praceta Prof. Mota Pinto, 3000-075 Coimbra, Portugal.
Rheumatology Department, Centro Hospitalar e Universitário de Coimbra (CHUC), Faculty of Medicine, University of Coimbra, Praceta Prof. Mota Pinto, 3000-075 Coimbra, Portugal.
Int J Surg Case Rep. 2016;19:31-4. doi: 10.1016/j.ijscr.2015.12.008. Epub 2015 Dec 14.
Lord total hip prosthesis was discontinued due to high revision rates of the smooth threaded acetabular component and negative effects of stress shielding in the proximal femur.
We report the outcome of a Lord cementless femoral stem, in a 55-year-old woman. In 1984, the patient underwent a Lord total hip arthroplasty for the treatment of advanced dysplastic osteoarthritis of the left hip. After 12 years, the cementless acetabular component of the prosthesis had been revised due to aseptic loosening. An acetabular metallic support ring and a cemented polyethylene cup were implanted, the femoral stem was not changed. The acetabular bone loss was reconstructed with morsellised cancellous bone allografts by the impacting technique. No complications were reported during the period of 19 years of the postoperative course. At the last clinical and radiological evaluations, the patient presented an asymptomatic hip and expressed high degree of satisfaction with the surgery result. The femoral stem was stable, with no measurable subsidence or radiolucent lines around the stem.
Several reports have presented a high clinical success rate with the fully-porous-coated Lord femoral stem in both primary and revision cases. However, the long-term results showed a substantial rate of proximal femoral bone loss and thigh pain.
In our case, the Lord stem showed an excellent long-term result at the 31-year follow-up. To our knowledge, there is no published report with results of the Lord stem longer than 26-year's follow-up.
由于光滑螺纹髋臼组件的高翻修率以及股骨近端应力遮挡的负面影响,Lord全髋关节假体已停产。
我们报告了一名55岁女性使用Lord非骨水泥型股骨柄的结果。1984年,该患者接受了Lord全髋关节置换术以治疗左髋晚期发育不良性骨关节炎。12年后,假体的非骨水泥髋臼组件因无菌性松动而进行了翻修。植入了髋臼金属支撑环和骨水泥固定的聚乙烯杯,股骨柄未更换。通过冲击技术用碎松质骨同种异体骨重建髋臼骨缺损。术后19年期间未报告任何并发症。在最后一次临床和影像学评估中,患者髋关节无症状,对手术结果表示高度满意。股骨柄稳定,柄周围无明显下沉或透亮线。
几份报告显示,全多孔涂层Lord股骨柄在初次和翻修病例中均具有较高的临床成功率。然而,长期结果显示股骨近端骨丢失和大腿疼痛的发生率较高。
在我们的病例中,Lord柄在31年的随访中显示出优异的长期结果。据我们所知,尚无关于Lord柄随访结果超过26年的已发表报告。