Guo Hongyue, Riter Leah S, Wujcik Chad E, Armstrong Daniel W
Monsanto Company, St Louis, MO, United States; University of Texas at Arlington, Arlington, TX, United States.
Monsanto Company, St Louis, MO, United States.
Talanta. 2016;149:103-109. doi: 10.1016/j.talanta.2015.11.043. Epub 2015 Nov 18.
A sensitive and selective HPLC-MS/MS method was developed for the quantitative analysis of dicamba residues in raw agricultural commodities (RACs). Instead of analysis in the traditionally used negative electrospray ionization (ESI) mode, these anionic compounds were detected in positive ESI with the use of ion-pairing reagents. In this approach, only a small amount (60µM) of a commercially available dicationic ion-pairing reagent was introduced into the post-column sample stream. This method has been validated in six different types of RACs including corn grain, corn stover, cotton seed, soybean, soy forage and orange with satisfactory quantitative accuracy and precision. The limits of quantitation (LOQ) values for these analytes were 1.0 to 3.0µg/kg. The standard curves were linear over the range of the tested concentrations (3.0 to 500µg/kg), with correlation coefficient (r) values≥0.999. Evaluation of ionization effects in RAC matrix extracts using diluent blanks for comparison showed no significant matrix effects were present.
建立了一种灵敏且具选择性的高效液相色谱-串联质谱法(HPLC-MS/MS),用于定量分析农产品原料(RACs)中的麦草畏残留。这些阴离子化合物并非采用传统的负电喷雾电离(ESI)模式进行分析,而是在正ESI模式下借助离子对试剂进行检测。在此方法中,仅将少量(60µM)市售的双阳离子离子对试剂引入柱后样品流中。该方法已在包括玉米粒、玉米秸秆、棉籽、大豆、大豆饲料和橙子在内的六种不同类型的RACs中得到验证,定量准确度和精密度令人满意。这些分析物的定量限(LOQ)值为1.0至3.0µg/kg。标准曲线在测试浓度范围(3.0至500µg/kg)内呈线性,相关系数(r)值≥0.999。使用稀释剂空白对比评估RAC基质提取物中的电离效应,结果表明不存在显著的基质效应。