• 文献检索
  • 文档翻译
  • 深度研究
  • 学术资讯
  • Suppr Zotero 插件Zotero 插件
  • 邀请有礼
  • 套餐&价格
  • 历史记录
应用&插件
Suppr Zotero 插件Zotero 插件浏览器插件Mac 客户端Windows 客户端微信小程序
定价
高级版会员购买积分包购买API积分包
服务
文献检索文档翻译深度研究API 文档MCP 服务
关于我们
关于 Suppr公司介绍联系我们用户协议隐私条款
关注我们

Suppr 超能文献

核心技术专利:CN118964589B侵权必究
粤ICP备2023148730 号-1Suppr @ 2026

文献检索

告别复杂PubMed语法,用中文像聊天一样搜索,搜遍4000万医学文献。AI智能推荐,让科研检索更轻松。

立即免费搜索

文件翻译

保留排版,准确专业,支持PDF/Word/PPT等文件格式,支持 12+语言互译。

免费翻译文档

深度研究

AI帮你快速写综述,25分钟生成高质量综述,智能提取关键信息,辅助科研写作。

立即免费体验

X-ray focal spot reconstruction by circular penumbra analysis-Application to digital radiography systems.

作者信息

Di Domenico Giovanni, Cardarelli Paolo, Contillo Adriano, Taibi Angelo, Gambaccini Mauro

机构信息

Dipartimento di Fisica e Scienze della Terra, Università degli Studi di Ferrara, via Saragat 1, FE I-44122, Italy and INFN - sezione di Ferrara, via Saragat 1, FE I-44122, Italy.

Dipartimento di Fisica e Scienze della Terra, Università degli Studi di Ferrara, via Saragat 1, FE I-44122, Italy.

出版信息

Med Phys. 2016 Jan;43(1):294. doi: 10.1118/1.4938414.

DOI:10.1118/1.4938414
PMID:26745922
Abstract

PURPOSE

The quality of a radiography system is affected by several factors, a major one being the focal spot size of the x-ray tube. In fact, the measurement of such size is recognized to be of primary importance during acceptance tests and image quality evaluations of clinical radiography systems. The most common device providing an image of the focal spot emission distribution is a pin-hole camera, which requires a high tube loading in order to produce a measurable signal. This work introduces an alternative technique to obtain an image of the focal spot, through the processing of a single radiograph of a simple test object, acquired with a suitable magnification.

METHODS

The radiograph of a magnified sharp edge is a well-established method to evaluate the extension of the focal spot profile along the direction perpendicular to the edge. From a single radiograph of a circular x-ray absorber, it is possible to extract simultaneously the radial profiles of several sharp edges with different orientations. The authors propose a technique that allows to obtain an image of the focal spot through the processing of these radial profiles by means of a pseudo-CT reconstruction technique. In order to validate this technique, the reconstruction has been applied to the simulated radiographs of an ideal disk-shaped absorber, generated by various simulated focal spot distributions. Furthermore, the method has been applied to the focal spot of a commercially available mammography unit.

RESULTS

In the case of simulated radiographs, the results of the reconstructions have been compared to the original distributions, showing an excellent agreement for what regards both the overall distribution and the full width at half maximum measurements. In the case of the experimental test, the method allowed to obtain images of the focal spot that have been compared with the results obtained through standard techniques, namely, pin-hole camera and slit camera.

CONCLUSIONS

The method was proven to be effective for simulated images and the results of the experimental test suggest that it could be considered as an alternative technique for focal spot distribution evaluation. The method offers the possibility to measure the actual focal spot size and emission distribution at the same exposure conditions as clinical routine, avoiding high tube loading as in the case of the pin-hole imaging technique.

摘要

相似文献

1
X-ray focal spot reconstruction by circular penumbra analysis-Application to digital radiography systems.
Med Phys. 2016 Jan;43(1):294. doi: 10.1118/1.4938414.
2
Method for measuring the focal spot size of an x-ray tube using a coded aperture mask and a digital detector.使用编码孔径掩模和数字探测器测量 X 射线管焦点尺寸的方法。
Med Phys. 2011 Apr;38(4):2099-115. doi: 10.1118/1.3567503.
3
Measurement of focal spot size with slit camera using computed radiography and flat-panel based digital detectors.使用计算机X线摄影和基于平板的数字探测器通过狭缝相机测量焦点尺寸。
Med Phys. 2003 Jul;30(7):1768-75. doi: 10.1118/1.1579583.
4
Imaging properties of digital magnification radiography.数字放大射线摄影术的成像特性。
Med Phys. 2006 Apr;33(4):984-96. doi: 10.1118/1.2174133.
5
Dual focal-spot imaging for phase extraction in phase-contrast radiography.用于相衬X射线摄影术中相位提取的双焦点成像。
Med Phys. 2003 Sep;30(9):2292-6. doi: 10.1118/1.1598672.
6
Effects of ray profile modeling on resolution recovery in clinical CT.射线轮廓建模对临床 CT 中分辨率恢复的影响。
Med Phys. 2014 Feb;41(2):021907. doi: 10.1118/1.4862510.
7
[X-ray phase imaging using a X-ray tube with a small focal spot -improvement of image quality in mammography-].[使用具有小焦点的X射线管进行X射线相位成像——乳腺摄影图像质量的改善——]
Igaku Butsuri. 2002;22(1):21-9.
8
Evaluation of x-ray effective focal spot size dependency on x-ray exposure settings using edge response analysis.
Radiol Phys Technol. 2023 Mar;16(1):39-47. doi: 10.1007/s12194-022-00688-w. Epub 2022 Dec 14.
9
Quantification of the effect of system and object parameters on edge enhancement in phase-contrast radiography.相位对比X射线摄影中系统和物体参数对边缘增强效果的量化
Med Phys. 2003 Nov;30(11):2888-96. doi: 10.1118/1.1617430.
10
Comparison of testing of collimator and beam alignment, focal spot size with slit camera, and tube current consistency using computed radiography and conventional screen-film systems.使用计算机放射摄影和传统屏-片系统比较准直器和射束准直、焦点大小与狭缝相机以及管电流一致性的检测。
J Appl Clin Med Phys. 2019 Jun;20(6):160-169. doi: 10.1002/acm2.12600. Epub 2019 May 16.

引用本文的文献

1
Evaluation of x-ray effective focal spot size dependency on x-ray exposure settings using edge response analysis.
Radiol Phys Technol. 2023 Mar;16(1):39-47. doi: 10.1007/s12194-022-00688-w. Epub 2022 Dec 14.
2
Characterization of x-ray focal spots using a rotating edge.使用旋转边缘对X射线焦点进行表征。
J Med Imaging (Bellingham). 2021 Mar;8(2):023502. doi: 10.1117/1.JMI.8.2.023502. Epub 2021 Mar 25.
3
Measurement of the x-ray effective focal spot size with edge response analysis using digital detectors.使用数字探测器通过边缘响应分析测量X射线有效焦点尺寸
J Med Imaging (Bellingham). 2020 Mar;7(2):023502. doi: 10.1117/1.JMI.7.2.023502. Epub 2020 Mar 23.