Abstract

BACKGROUND

We aimed to report the image quality, relationship between heart rate and image quality, amount of contrast agent given to the patients and radiation doses in coronary CT angiography (CTA) obtained by using high-pitch prospectively ECG-gated "Flash Spiral" technique (method A) or retrospectively ECG-gated technique (method B) using 128×2-slice dual-source CT.

MATERIAL/METHODS: A total of 110 patients who were evaluated with method A and method B technique with a 128×2-detector dual-source CT device were included in the study. Patients were divided into three groups based on their heart rates during the procedure, and a relationship between heart rate and image quality were evaluated. The relationship between heart rate, gender and radiation dose received by the patients was compared.

RESULTS

A total of 1760 segments were evaluated in terms of image quality. Comparison of the relationship between heart rate and image quality revealed a significant difference between heart rate <60 beats/min group and >75 beats/min group whereas <60 beats/min and 60-75 beats/min groups did not differ significantly. The average effective dose for coronary CTA was calculated as 1.11 mSv (0.47-2.01 mSv) for method A and 8.22 mSv (2.19-12.88 mSv) for method B.

CONCLUSIONS

Method A provided high quality images with doses as low as <1 mSv in selected patients who have low heart rates with a high negative predictive value to rule out coronary artery disease. Although method B increases the amount of effective dose, it provides high diagnostic quality images for patients who have a high heart rate and arrhythmia which makes it is difficult to obtain images.

摘要

背景

我们旨在报告使用高螺距前瞻性心电图门控“Flash螺旋”技术(方法A)或回顾性心电图门控技术(方法B),通过128×2层双源CT进行冠状动脉CT血管造影(CTA)时的图像质量、心率与图像质量的关系、给予患者的对比剂用量以及辐射剂量。

材料/方法:本研究纳入了110例使用128×2探测器双源CT设备采用方法A和方法B技术进行评估的患者。根据患者检查过程中的心率将其分为三组,并评估心率与图像质量之间的关系。比较了心率、性别与患者接受的辐射剂量之间的关系。

结果

共评估了1760个节段的图像质量。心率与图像质量关系的比较显示,心率<60次/分钟组与>75次/分钟组之间存在显著差异,而<60次/分钟组与60 - 75次/分钟组之间无显著差异。冠状动脉CTA的平均有效剂量,方法A计算为1.11 mSv(0.47 - 2.01 mSv),方法B为8.22 mSv(2.19 - 12.88 mSv)。

结论

方法A为心率较低的特定患者提供了高质量图像,剂量低至<1 mSv,对排除冠状动脉疾病具有较高的阴性预测价值。虽然方法B增加了有效剂量,但它为心率高和有心律失常、难以获得图像的患者提供了高诊断质量的图像。