Pereira Sandra, Preto César, Pinho Carla, Vasconcelos Pedro
Department of Anesthesiology, Centro Hospitalar do Tâmega e Sousa, Penafiel, Portugal.
Department of Anesthesiology, Centro Hospitalar do Tâmega e Sousa, Penafiel, Portugal.
Braz J Anesthesiol. 2016 Jan-Feb;66(1):78-81. doi: 10.1016/j.bjane.2014.02.007. Epub 2014 Mar 6.
We present two cases of misplaced central venous catheters having in common the absence of free blood return from one lumen immediately after placement. The former is a case of right hydrothorax associated with central venous catheterization with the catheter tip in intra-pleural location. In this case the distal port was never patent. In the latter case there was an increased aspiration pressure through the middle port due to a catheter looping. The absence of free flow on aspiration from one lumen of a central catheter should not be undervalued. In these circumstances the catheter should not be used and needs to be removed.
我们报告两例中心静脉导管位置不当的病例,其共同特点是置管后立即有一个管腔无回血。前者是与中心静脉置管相关的右侧胸腔积液病例,导管尖端位于胸腔内。在这种情况下,远端端口从未通畅。在后者中,由于导管盘绕,通过中间端口的抽吸压力增加。中心静脉导管一个管腔抽吸时无回血这一情况不应被忽视。在这些情况下,不应使用该导管,需要将其拔除。