Suppr超能文献

三种测定人血清中光动力治疗药物2-[1-己氧基乙基]-2-去乙烯基焦脱镁叶绿酸-a(HPPH)的新方法的建立与比较。

Establishment and comparison of three novel methods for the determination of the photodynamic therapy agent 2-[1-hexyloxyethyl]-2-devinyl pyropheophorbide-a (HPPH) in human serum.

作者信息

Chen Lin, Xiao Qingqing, Zhang Xian, Yang Jin

机构信息

Center of Drug Metabolism and Pharmacokinetics, China Pharmaceutical University, Nanjing 210009, China.

Department of Clinical Pharmacy, School of Pharmacy, China Pharmaceutical University, Nanjing 210009, China.

出版信息

J Pharm Biomed Anal. 2016 Mar 20;121:13-21. doi: 10.1016/j.jpba.2015.12.057. Epub 2016 Jan 3.

Abstract

2-[1-Hexyloxyethyl]-2-devinyl pyropheophorbide-a (HPPH) is a second-generation photosensitizer that has been applied in clinical studies of photodynamic therapy for a variety of malignant lesions. Based on the differences in selectivity and labour intensity, three novel methods - fluorescence detection coupled with high performance liquid chromatography (LC-FLD), LC-tandem mass spectrometry (LC-MS/MS) and fluorescence-based microplate reader methods - were developed for the determination of HPPH in human serum, which allowed comparison of fluorescence and MS platform for HPPH quantification. All three methods have been validated and successfully applied to support the clinical pharmacokinetic study of HPPH. The concentrations measured by LC-FLD matched those by LC-MS/MS with a correlation coefficient (r=0.994) and coefficient of determination (r(2)=0.989). Data consistency was also found between the measurements of microplate reader and LC-MS/MS with a correlation coefficient (r=0.999) and coefficient of determination (r(2)=0.998), indicating that fluorescence assay, the low cost alternative with a relatively poorer selectivity, is clearly suitable for the quantification of HPPH. Calibration curves in the methods of LC-FLD and microplate reader were linear (r˃0.998) over the concentration range from 50 to 5000 ng/mL, and linearity was obtained over the concentration range from 5 to 1000 ng/mL in the LC-MS/MS method. Compared with the other two methods, the fluorescence-based microplate reader method with proven high selectivity should be strongly recommended because of obvious advantages such as the lowest labour intensity, the lowest instrument cost, a better sensitivity than LC-FLD and the very rapid determination of large number of samples (24 samples/40 s).

摘要

2-[1-己氧基乙基]-2-去乙烯基焦脱镁叶绿酸-a(HPPH)是一种第二代光敏剂,已应用于多种恶性病变的光动力治疗临床研究。基于选择性和劳动强度的差异,开发了三种新方法——高效液相色谱荧光检测法(LC-FLD)、液相色谱串联质谱法(LC-MS/MS)和基于荧光的酶标仪法——用于测定人血清中的HPPH,从而能够比较荧光和质谱平台对HPPH的定量分析。这三种方法均已得到验证,并成功应用于支持HPPH的临床药代动力学研究。LC-FLD测得的浓度与LC-MS/MS测得的浓度相匹配,相关系数(r = 0.994)和决定系数(r² = 0.989)。酶标仪和LC-MS/MS的测量结果之间也发现了数据一致性,相关系数(r = 0.999)和决定系数(r² = 0.998),表明荧光分析法作为选择性相对较差但成本较低的替代方法,显然适用于HPPH的定量分析。LC-FLD法和酶标仪法的校准曲线在50至5000 ng/mL的浓度范围内呈线性(r>0.998),LC-MS/MS法在5至1000 ng/mL的浓度范围内获得线性。与其他两种方法相比,基于荧光的酶标仪法具有高选择性,应强烈推荐,因为它具有明显的优势,如劳动强度最低、仪器成本最低、比LC-FLD具有更好的灵敏度以及能够非常快速地测定大量样品(24个样品/40秒)。

文献AI研究员

20分钟写一篇综述,助力文献阅读效率提升50倍。

立即体验

用中文搜PubMed

大模型驱动的PubMed中文搜索引擎

马上搜索

文档翻译

学术文献翻译模型,支持多种主流文档格式。

立即体验