Suppr超能文献

洛多克斯/扫描式计算机X线体层摄影有助于早期发现创伤性脑损伤患者中常见的被忽视的颅外损伤。

Lodox/Statscan facilitates the early detection of commonly overlooked extracranial injuries in patients with traumatic brain injury.

作者信息

Huang H-C, Fu C-Y, Hsieh C-H, Wang Y-C, Wu S-C, Chen R-J, Huang J-C

机构信息

Trauma and Emergency Center, China Medical University Hospital, No. 2 Yuh-Der Road, Taichung, 404, Taiwan, ROC.

Trauma and Emergency Surgery Department, Taipei Medical University, Wan Fang Hospital, No. 111, Section 3, Hsing Long Rd, Taipei, 116, Taiwan, ROC.

出版信息

Eur J Trauma Emerg Surg. 2012 Jun;38(3):319-26. doi: 10.1007/s00068-012-0176-z. Epub 2012 Feb 3.

Abstract

INTRODUCTION

Traumatic brain injury (TBI) is a common diagnosis in the emergency department. Brain computed tomography (CT) has become a standard diagnostic tool with which to examine TBI patients. Conventional X-rays are ineffective for the evaluation of torso or extremity injuries. In the current study, we attempted to establish a diagnostic modality to evaluate systemically initially unconscious patients in the emergency department with a rapid screening technique characterized by sufficient information, low cost and low radiation exposure.

MATERIALS AND METHODS

From January 2008 to December 2009, patients with diminished level of consciousness received the Lodox/Statscan for evaluation of extracranial injuries were enrolled in this study. The accuracy of this diagnostic modality in detecting torso or extremity injuries in initially unconscious patients was analyzed by comparing the initial diagnosis (by the Lodox/Statscan) with the final diagnosis (confirmed by torso CT scan or after two weeks of follow-up).

RESULTS

There were 1,210 patients with TBI whose extracranial injuries were evaluated by the Lodox/Statscan. After excluding intra-abdominal injuries, the overall sensitivity rates of the Lodox/Statscan in diagnosing torso injuries and extremity injuries were 89.7% and 90.2%, respectively. No long bone fracture was missed by the Lodox/Statscan. The sensitivity and specificity of the Lodox/Statscan in diagnosing long bone fractures were both 100%. Most patients with torso injuries that were missed by the Lodox/Statscan could be managed conservatively without further treatment or complications. All of the missed extremity injuries were distal bone fractures.

CONCLUSION

The Lodox/Statscan can provide benefits for surveying extracranial injuries in patients with diminished level of consciousness. The Lodox/Statscan also emits a notably low dose of radiation and appears to be a relatively inexpensive adjunct to screen torso or extremity injuries in TBI patients.

摘要

引言

创伤性脑损伤(TBI)是急诊科常见的诊断病例。脑部计算机断层扫描(CT)已成为检查TBI患者的标准诊断工具。传统X射线对躯干或四肢损伤的评估无效。在本研究中,我们试图建立一种诊断方法,通过一种具有信息充分、成本低和辐射暴露低特点的快速筛查技术,对急诊科最初无意识的患者进行全身评估。

材料与方法

2008年1月至2009年12月,意识水平下降且接受Lodox/Statscan评估颅外损伤的患者纳入本研究。通过将初始诊断(由Lodox/Statscan做出)与最终诊断(经躯干CT扫描确认或随访两周后确认)进行比较,分析这种诊断方法在检测最初无意识患者的躯干或四肢损伤方面的准确性。

结果

有1210例TBI患者的颅外损伤通过Lodox/Statscan进行了评估。排除腹部损伤后,Lodox/Statscan诊断躯干损伤和四肢损伤的总体灵敏度分别为89.7%和90.2%。Lodox/Statscan没有漏诊任何长骨骨折。Lodox/Statscan诊断长骨骨折的灵敏度和特异度均为100%。Lodox/Statscan漏诊的大多数躯干损伤患者可以保守治疗,无需进一步治疗或出现并发症。所有漏诊的四肢损伤均为远端骨折。

结论

Lodox/Statscan可为评估意识水平下降患者的颅外损伤提供帮助。Lodox/Statscan还能显著降低辐射剂量,似乎是一种相对廉价的辅助手段,用于筛查TBI患者的躯干或四肢损伤。