Suppr超能文献

新型软件辅助评估膀胱癌盆腔动脉化疗灌注期间的盆腔血流动力学:双球囊与单球囊技术

Novel Software-Assisted Hemodynamic Evaluation of Pelvic Flow During Chemoperfusion of Pelvic Arteries for Bladder Cancer: Double- Versus Single-Balloon Technique.

作者信息

Yamamoto Kiyohito, Yamamoto Kazuhiro, Nakai Go, Azuma Haruhito, Narumi Yoshifumi

机构信息

Department of Radiology, Osaka Medical College, 2-7, Daigakumachi, Takatsuki-City, Osaka, 569-8686, Japan.

Department of Urology, Osaka Medical College, 2-7, Daigakumachi, Takatsuki-City, Osaka, 569-8686, Japan.

出版信息

Cardiovasc Intervent Radiol. 2016 Jun;39(6):824-30. doi: 10.1007/s00270-016-1296-3. Epub 2016 Jan 27.

Abstract

PURPOSE

Approximately 83 % of patients with bladder cancer have achieved a complete response after undergoing a novel bladder preservation therapy involving balloon-occluded intra-arterial infusion chemotherapy (BOAI) using a four-lumen double-balloon catheter, known as the Osaka Medical College regimen. This study aimed to show the quantitative difference in hemodynamics of the bladder arteries using syngo iFlow (Siemens Healthcare, Erlangen, Germany), which provides an automatic tool for quantitative blood flow analysis between double BOAI (D-BOAI) and conventional single BOAI (S-BOAI).

MATERIALS AND METHODS

Fifty patients were included. The catheters were introduced into both posterior trunks of the internal iliac arteries via contralateral femoral artery access. A side hole between the distal and proximal balloons was placed at the origin of each bladder artery to allow clear visualization of angiographic flow of the injected agent into the urinary bladder. Digital subtraction angiography was used during analysis with the syngo iFlow to evaluate the hemodynamics of the contrast medium in the pelvic arteries during BOAI. The comparative change in the amount of contrast medium in the bladder arteries between D-BOAI and S-BOAI was assessed using syngo iFlow.

RESULTS

One-hundred pelvic sides were analyzed. The amount of contrast medium in the bladder arteries using D-BOAI was more than twice that using S-BOAI (right, 3.03-fold; left, 2.81-fold).

CONCLUSION

The amount of contrast medium in the bladder arteries using D-BOAI was higher than that using conventional S-BOAI. This may increase the anticancer drug concentration in the affected bladder, leading to a good clinical response.

摘要

目的

约83%的膀胱癌患者在接受一种新型膀胱保留疗法后实现了完全缓解,该疗法采用四腔双球囊导管进行球囊阻断动脉内灌注化疗(BOAI),即大阪医科大学方案。本研究旨在利用syngo iFlow(德国埃尔朗根西门子医疗公司)显示膀胱动脉血流动力学的定量差异,该软件为双球囊阻断动脉内灌注化疗(D - BOAI)和传统单球囊阻断动脉内灌注化疗(S - BOAI)之间的血流定量分析提供了自动工具。

材料与方法

纳入50例患者。通过对侧股动脉穿刺将导管插入双侧髂内动脉后干。在每条膀胱动脉起始处的远近端球囊之间设置一个侧孔,以便清晰观察注入剂进入膀胱的血管造影血流。在使用syngo iFlow进行分析期间,采用数字减影血管造影术评估球囊阻断动脉内灌注化疗期间盆腔动脉内造影剂的血流动力学。使用syngo iFlow评估D - BOAI和S - BOAI之间膀胱动脉内造影剂含量的比较变化。

结果

分析了100侧盆腔。使用D - BOAI时膀胱动脉内造影剂的含量是使用S - BOAI时的两倍多(右侧为3.03倍;左侧为2.81倍)。

结论

使用D - BOAI时膀胱动脉内造影剂的含量高于传统S - BOAI。这可能会增加患侧膀胱内的抗癌药物浓度,从而带来良好的临床反应。

https://cdn.ncbi.nlm.nih.gov/pmc/blobs/fe85/4858555/f96b39944c19/270_2016_1296_Fig1_HTML.jpg

文献检索

告别复杂PubMed语法,用中文像聊天一样搜索,搜遍4000万医学文献。AI智能推荐,让科研检索更轻松。

立即免费搜索

文件翻译

保留排版,准确专业,支持PDF/Word/PPT等文件格式,支持 12+语言互译。

免费翻译文档

深度研究

AI帮你快速写综述,25分钟生成高质量综述,智能提取关键信息,辅助科研写作。

立即免费体验