PURPOSE

Muscle vibration is a technique that applies a low-amplitude/high-frequency vibratory stimulus to a specific muscle using a mechanical device. The aim of this study was to evaluate, using robot-based outcomes, the effects of focal muscle vibration, at different frequencies, on the motor performance of the upper limb in healthy subjects.

METHODS

Forty-eight volunteer healthy subjects (age: 31 ± 8 years) were enrolled. Subjects were assigned to three different groups: the first group, in which subjects underwent muscle vibration treatment with a frequency of 100 Hz; the second group of subjects underwent the same treatment protocol, but using a frequency of vibration of 200 Hz; finally, the control group did not undergo any treatment. The robot-based evaluation session consisted of visually guided reaching task, performed in the sagittal plane.

RESULTS

Our results showed that the vibration treatment improved upper limb motor performance of healthy subjects from the baseline (T0) to 10 days after the end of the treatment (T2), but only the group treated with a frequency of 200 Hz reached statistical significance. Specifically, in this group we found an increase of the number of repetitions (T0: 51.4 ± 22.7; T2: 66.3 ± 11.8), and the smoothness of the movement, as showed by a decrease of the Normalized Jerk (T0: 10.5 ± 2.8; T2: 7.7 ± 0.5).

CONCLUSION

The results of our study support the use of focal muscle vibration protocols in healthy subjects, to improve motor performance.

摘要

目的

肌肉振动是一种使用机械设备对特定肌肉施加低振幅/高频振动刺激的技术。本研究的目的是使用基于机器人的结果评估不同频率的局部肌肉振动对健康受试者上肢运动表现的影响。

方法

招募了48名健康志愿者(年龄:31±8岁)。受试者被分为三组:第一组受试者接受频率为100Hz的肌肉振动治疗;第二组受试者接受相同的治疗方案,但振动频率为200Hz;最后,对照组不接受任何治疗。基于机器人的评估环节包括在矢状面进行的视觉引导伸手任务。

结果

我们的结果表明,振动治疗改善了健康受试者从基线(T0)到治疗结束后10天(T2)的上肢运动表现,但只有频率为200Hz的治疗组达到了统计学意义。具体而言,在该组中我们发现重复次数增加(T0:51.4±22.7;T2:66.3±11.8),并且运动的平滑度提高,这表现为归一化急动度降低(T0:10.5±2.8;T2:7.7±0.5)。

结论

我们的研究结果支持在健康受试者中使用局部肌肉振动方案来改善运动表现。