Suppr超能文献

THERMOCOOL® SMARTTOUCH® 导管——接触力技术及VISITAG™ 模块作用的现有证据

THERMOCOOL® SMARTTOUCH® CATHETER - The Evidence So Far for Contact Force Technology and the Role of VISITAG™ MODULE.

作者信息

Lin Tina, Ouyang Feifan, Kuck Karl-Heinz, Tilz Roland

机构信息

Electrophysiology Fellow.

Electrophysiologist.

出版信息

Arrhythm Electrophysiol Rev. 2014 May;3(1):44-7. doi: 10.15420/aer.2011.3.1.44. Epub 2014 May 30.

Abstract

Catheter ablation has become an important modality in the treatment of most cardiac arrhythmias. In recent years there has been significant development of new ablation energies and technologies in an attempt to improve clinical outcomes and decrease disease burden. Ablation failure is often associated with inadequate lesion formation, and catheter-to-myocardial contact force (CF) and catheter stability are two of the parameters required to produce effective lesions during radiofrequency energy application. Recently, CF sensing catheters and tagging modules have been developed to give operators realtime data on catheter force and stability. This review describes the novel THERMOCOOL(®) SMARTTOUCH(®) CATHETER (Biosense Webster Inc., CA, US) and VISITAG™ MODULE (Biosense Webster Inc., CA, US) software, and discusses the results of several studies on CF and catheter stability during mapping and ablation of the left atrium and ventricle from our electrophysiology laboratory. We assess the short- and longer-term outcomes during mapping and ablation with and without CF data, as well as the use of the VISITAG MODULE™ software, which allows the evaluation of multiple parameters of lesion formation, then integrates and displays this as automatic tags in a relatively objective way.

摘要

导管消融已成为治疗大多数心律失常的重要手段。近年来,为了改善临床疗效并减轻疾病负担,新型消融能量和技术有了显著发展。消融失败通常与病变形成不充分有关,而导管与心肌的接触力(CF)和导管稳定性是在应用射频能量期间产生有效病变所需的两个参数。最近,已开发出CF感应导管和标记模块,以便为操作人员提供有关导管力和稳定性的实时数据。本综述介绍了新型THERMOCOOL(®) SMARTTOUCH(®)导管(美国加利福尼亚州Biosense Webster公司)和VISITAG™模块(美国加利福尼亚州Biosense Webster公司)软件,并讨论了我们电生理实验室关于左心房和心室标测与消融期间CF和导管稳定性的多项研究结果。我们评估了有无CF数据时标测与消融的短期和长期结果,以及VISITAG模块™软件的使用情况,该软件允许评估病变形成的多个参数,然后以相对客观的方式将其整合并显示为自动标记。

相似文献

1
THERMOCOOL® SMARTTOUCH® CATHETER - The Evidence So Far for Contact Force Technology and the Role of VISITAG™ MODULE.
Arrhythm Electrophysiol Rev. 2014 May;3(1):44-7. doi: 10.15420/aer.2011.3.1.44. Epub 2014 May 30.
6
Impact of Contact Force Monitoring in Acute Pulmonary Vein Isolation Using an Anatomic Approach. A Randomized Study.
Pacing Clin Electrophysiol. 2016 Apr;39(4):361-9. doi: 10.1111/pace.12811. Epub 2016 Feb 18.
7
Evaluation of Ablation Parameters to Predict Irreversible Lesion Size During Pulsed Field Ablation.
Circ Arrhythm Electrophysiol. 2024 Aug;17(8):e012814. doi: 10.1161/CIRCEP.124.012814. Epub 2024 Jul 25.
9
Contact force sensing in ablation of ventricular arrhythmias using a 56-hole open-irrigation catheter: a propensity-matched analysis.
J Interv Card Electrophysiol. 2021 Apr;60(3):543-553. doi: 10.1007/s10840-020-00756-4. Epub 2020 May 21.

引用本文的文献

1
Machine-Learning-Based Multi-Modal Force Estimation for Steerable Ablation Catheters.
IEEE Trans Med Robot Bionics. 2024 Aug;6(3):1004-1016. doi: 10.1109/tmrb.2024.3407590. Epub 2024 May 31.
2
Catheter inversion during cavotricuspid isthmus catheter ablation: The new shaft visualization catheter reduces fluoroscopy use.
J Arrhythm. 2021 Jul 11;37(5):1311-1317. doi: 10.1002/joa3.12596. eCollection 2021 Oct.
3
Technical Note: On Cardiac Ablation Lesion Visualization for Image-guided Therapy Monitoring.
Proc SPIE Int Soc Opt Eng. 2018 Feb;10576. doi: 10.1117/12.2322523. Epub 2018 Mar 13.
4
The Impact of Advances in Atrial Fibrillation Ablation Devices on the Incidence and Prevention of Complications.
Arrhythm Electrophysiol Rev. 2018 Aug;7(3):169-180. doi: 10.15420/aer.2018.7.3.
5
Contact force-sensing catheters: performance in an ex vivo porcine heart model.
J Interv Card Electrophysiol. 2018 Nov;53(2):141-150. doi: 10.1007/s10840-018-0435-y. Epub 2018 Aug 14.
6
3D Mapping for PVI- Geometry, Image Integration and Incorporation of Contact Force Into Work Flow.
J Atr Fibrillation. 2018 Apr 30;10(6):1795. doi: 10.4022/jafib.1795. eCollection 2018 Apr.
8
Lesion modeling, characterization, and visualization for image-guided cardiac ablation therapy monitoring.
J Med Imaging (Bellingham). 2018 Apr;5(2):021218. doi: 10.1117/1.JMI.5.2.021218. Epub 2018 Mar 1.

本文引用的文献

2
Long-term outcomes following high intensity focused ultrasound ablation for atrial fibrillation.
J Card Surg. 2014 Jan;29(1):101-7. doi: 10.1111/jocs.12234. Epub 2013 Oct 24.
3
In vivo contact force analysis and correlation with tissue impedance during left atrial mapping and catheter ablation of atrial fibrillation.
Circ Arrhythm Electrophysiol. 2014 Feb;7(1):46-54. doi: 10.1161/CIRCEP.113.000556. Epub 2013 Dec 20.
6
Pulmonary vein isolation using a visually guided laser balloon catheter: the first 200-patient multicenter clinical experience.
Circ Arrhythm Electrophysiol. 2013 Jun;6(3):467-72. doi: 10.1161/CIRCEP.113.000431. Epub 2013 Apr 4.
7
Contact force monitoring for cardiac mapping in patients with ventricular tachycardia.
J Cardiovasc Electrophysiol. 2013 May;24(5):519-24. doi: 10.1111/jce.12080. Epub 2013 Feb 1.

文献AI研究员

20分钟写一篇综述,助力文献阅读效率提升50倍。

立即体验

用中文搜PubMed

大模型驱动的PubMed中文搜索引擎

马上搜索

文档翻译

学术文献翻译模型,支持多种主流文档格式。

立即体验