使用动态单通道肌电图设备对自我报告的磨牙症睡眠测量的诊断效度。

Diagnostic validity of self-reported measures of sleep bruxism using an ambulatory single-channel EMG device.

作者信息

Yachida Wataru, Arima Taro, Castrillon Eduardo E, Baad-Hansen Lene, Ohata Noboru, Svensson Peter

机构信息

Clinical Division of Crown and Bridge Prosthodontics Dentistry, Hokkaido University Hospital, Sapporo, Japan.

Division of International Affairs, Graduate School of Dental Medicine, Hokkaido University, Sapporo, Japan.

出版信息

J Prosthodont Res. 2016 Oct;60(4):250-257. doi: 10.1016/j.jpor.2016.01.001. Epub 2016 Feb 12.

Abstract

PURPOSE

Self-reported measures have been widely used to indicate the presence of possible and probable sleep bruxism (SB) in both research and clinical situations. However, few studies have attempted to assess the diagnostic validity of this approach. The aim of this study was to estimate the diagnostic validity of self-reported measures of SB using an ambulatory single-channel electromyographic (EMG) device.

METHODS

A total of 115 participants were enrolled and examined by standardized Research Diagnostic Criteria for Temporomandibular Disorders (RDC/TMD) including two questions related to SB: self-reported SB and morning-jaw symptoms. An ambulatory single-channel EMG device (GrindCare3™, Medotech A/S) was used for measuring jaw-muscle EMG activity during sleep for seven consecutive nights. Cut-off values for different measures of EMG activity (average, maximum and minimum) and the coefficient of variation (CV) were selected to divide participants into two groups, with higher or lower EMG activity or CV values. The sensitivity and specificity for each question and combination of them were calculated.

RESULTS

Self-reported SB had the highest sensitivity (compared with morning-jaw symptoms) for all measures of EMG activity and CV, although the values were low to modest (average: 76.0%, maximum: 76.9%, minimum: 77.3%, CV: 61.0%). The specificity was low for both the questions related to the different measures of EMG activity and CV (35.1-52.4%).

CONCLUSIONS

This study indicated that the diagnostic validity of self-reported measures of SB was low to modest using an ambulatory EMG device assessment as a reference. Using only self-reported measures for the assessment of SB may not have a high validity, which should be taken into consideration in the clinical evaluation of patients.

摘要

目的

在研究和临床环境中,自我报告的测量方法已被广泛用于表明可能存在的睡眠磨牙症(SB)。然而,很少有研究试图评估这种方法的诊断有效性。本研究的目的是使用便携式单通道肌电图(EMG)设备评估自我报告的SB测量方法的诊断有效性。

方法

共招募了115名参与者,并通过标准化的颞下颌关节紊乱研究诊断标准(RDC/TMD)进行检查,其中包括两个与SB相关的问题:自我报告的SB和晨起颌部症状。使用便携式单通道EMG设备(GrindCare3™,Medotech A/S)连续七个晚上测量睡眠期间的颌部肌肉EMG活动。选择不同EMG活动测量值(平均值、最大值和最小值)以及变异系数(CV)的临界值,将参与者分为两组,EMG活动或CV值较高或较低。计算每个问题及其组合的敏感性和特异性。

结果

对于所有EMG活动和CV测量值,自我报告的SB具有最高的敏感性(与晨起颌部症状相比),尽管这些值较低至中等(平均值:76.0%,最大值:76.9%,最小值:77.3%,CV:61.0%)。与不同EMG活动和CV测量值相关的两个问题的特异性均较低(35.1 - 52.4%)。

结论

本研究表明,以便携式EMG设备评估为参考,自我报告的SB测量方法的诊断有效性较低至中等。仅使用自我报告的测量方法评估SB可能没有很高的有效性,这在患者的临床评估中应予以考虑。