Suppr超能文献

睡眠磨牙症的检测:肌电图和心电图便携式动态心电图与多导睡眠图的比较。

Detection of sleep bruxism: comparison between an electromyographic and electrocardiographic portable holter and polysomnography.

机构信息

Department of Surgical Sciences, Specialization School of Orthodontics, Dental School, University of Torino, Torino, Italy.

出版信息

J Oral Rehabil. 2014 Mar;41(3):163-9. doi: 10.1111/joor.12131. Epub 2014 Jan 7.

Abstract

Recent polysomnographic (PSG) studies showed that the sleep bruxism (SB) event is preceded by a sudden shift in autonomic cardiac activity. Therefore, heart rate could be the simplest-to-record parameter for use in addition to portable home EMG monitoring to improve the accuracy in automatic detection of SB events. The aim of the study was to compare the detection of SB episodes by combined surface electromyography and heart rate (HR) recorded by a compact portable device (Bruxoff(®) ), with the scoring of SB episodes by a PSG recording. Twenty-five subjects (14 'probable' bruxers and 11 non-bruxers) were selected for the study. Each subject underwent the Bruxoff and the PSG recordings during the same night. Rhythmic masseter muscle activities (RMMAs) were scored according to published criteria. Correlation coefficients and the Bland-Altman plots were calculated to measure the correlation and agreement between the two methods. Results showed a high correlation (Pearson's r = 0·95, P < 0·0001) and a high agreement (bias = 0·05) between Bruxoff and the PSG. Furthermore, the receiver operating characteristic curve analysis showed a high sensitivity and specificity of the portable device (92·3% and 91·6%, respectively) when the cut-off was set at 4 SB episodes per hour according to published criteria. The Bruxoff device showed a good diagnostic accuracy to differentiate RMMA from other oromotor activities. These findings are important in the light of the need for simple and reliable portable devices for the diagnosis of SB both in the clinical and research settings.

摘要

最近的多导睡眠图(PSG)研究表明,睡眠磨牙症(SB)事件之前会突然出现自主心脏活动的转变。因此,心率可能是除便携式肌电图监测之外最简单的记录参数,可用于提高 SB 事件自动检测的准确性。本研究旨在比较使用紧凑便携式设备(Bruxoff(®))记录的表面肌电图和心率(HR)联合检测 SB 发作与 PSG 记录评分 SB 发作的检测效果。选择了 25 名受试者(14 名“可能”磨牙者和 11 名非磨牙者)进行研究。每位受试者均在同一晚接受 Bruxoff 和 PSG 记录。根据已发表的标准,对节律性咬肌肌电活动(RMMAs)进行评分。计算相关系数和 Bland-Altman 图以测量两种方法之间的相关性和一致性。结果显示,Bruxoff 与 PSG 之间具有高度相关性(Pearson's r = 0·95,P < 0·0001)和高度一致性(偏差= 0·05)。此外,根据已发表的标准,当将便携式设备的截断值设置为每小时 4 次 SB 发作时,该设备的接受者操作特征曲线分析显示出高敏感性和特异性(分别为 92.3%和 91.6%)。Bruxoff 设备具有很好的诊断准确性,可以区分 RMMA 与其他口颌运动活动。这些发现对于在临床和研究环境中诊断 SB 都需要简单可靠的便携式设备具有重要意义。

文献AI研究员

20分钟写一篇综述,助力文献阅读效率提升50倍。

立即体验

用中文搜PubMed

大模型驱动的PubMed中文搜索引擎

马上搜索

文档翻译

学术文献翻译模型,支持多种主流文档格式。

立即体验