Abstract

In view of assessing natural radioactivity with on-site quantitative gamma spectrometry, efficiency calibration of NaI(Tl) detectors is investigated. A calibration based on Monte Carlo simulation of detector response is proposed, to render reliable quantitative analysis practicable in field campaigns. The method is developed with reference to contact geometry, in which measurements are taken placing the NaI(Tl) probe directly against the solid source to be analyzed. The Monte Carlo code used for the simulations was MCNP. Experimental verification of the calibration goodness is obtained by comparison with appropriate standards, as reported. On-site measurements yield a quick quantitative assessment of natural radioactivity levels present ((40)K, (238)U and (232)Th). On-site gamma spectrometry can prove particularly useful insofar as it provides information on materials from which samples cannot be taken.

摘要

鉴于通过现场定量伽马能谱法评估天然放射性,对碘化钠(铊)探测器的效率校准进行了研究。提出了一种基于探测器响应蒙特卡罗模拟的校准方法,以使在野外作业中进行可靠的定量分析成为可能。该方法是针对接触几何结构开发的,即在测量时将碘化钠(铊)探头直接放置在待分析的固体源上。用于模拟的蒙特卡罗代码是MCNP。如报告所述,通过与适当标准进行比较获得了校准优度的实验验证。现场测量能够快速定量评估存在的天然放射性水平(钾-40、铀-238和钍-232)。现场伽马能谱法可能特别有用,因为它能提供有关无法采集样本的材料的信息。